background image

2

I. Introduction ............................................................................................................................................................................................ 2
II.  Safety Instructions and Warnings ........................................................................................................................................................... 2
III.  Features at a Glance ...........................................................................................................................................................................2-4
IV.  Use and Maintenance ..........................................................................................................................................................................4-6
V.  Troubleshooting Guide ............................................................................................................................................................................. 7
VI.  Replacement Parts ................................................................................................................................................................................. 7
VII.  Cambro Warranty and Product Liability ................................................................................................................................................... 8

Congratulations on the purchase of your new Camtherm

®

. This Owner’s Manual provides you with a step-by-step guide to operating and maintaining your new 

insulated transporter – versatile enough to hold hot or cold food. If you have any further questions, please contact your Cambro Sales Representative, visit www.
cambro.com or call our 

Customer Service Department at 800.833.3003 (International customers please call 714.848.1555).

I. Introduction

Table of Contents

IMPORTANT: 

Read all instructions prior to use and save for future reference. 

•  Not intended for use outdoors.
•  Follow all warnings marked on unit.
•  Use only type of power supply (voltage, phase, frequency) indicated on the heater unit label.
•  Do not use if power cord is frayed or damaged.
•  Connect unit to properly grounded power source.
•  Use only manufacturer authorized power cord and replacement parts.
• 

Warning!

 Do not use this equipment in wet or damp conditions. 

• 

Warning!

 Unplug unit prior to cleaning or service. 

• 

Warning!

 Remove power cord from heater prior to cleaning. Clean with damp cloth only. 

• 

Warning!

 Do not submerge heater in water and never spray water on or near it. 

• 

Warning!

 Do not get the thermometer wet in any way.

• 

Warning!

 Unplug the power cord before removing the interior louvers for cleaning.

• 

Warning!

 Only Cambro Authorized Service Agent or qualified foodservice equipment technician should open 

the inner cover of the heater for servicing.

• 

Caution! 

Outer surfaces of the thermoelectric unit may be HOT.

•  Any operating problems not identified and corrected by instructions in this manual should be referred to 

a qualified service personnel (electrician or foodservice equipment technician).

II. Safety Instructions and Warnings

III. Features at a Glance

(A) Back View 

1.  Thermoelectric Unit 
2.  Power Cord 
3.  Rear, Wheels (Option for rigid casters 
or big wheels on Tall carts only) 
4.  Rear Handles 
5.   Control Panel 
6.  Molded-in Bumper 

Low HOT Only Model

Tall HOT/COLD Model

Summary of Contents for Camtherm Series

Page 1: ...26LC Hot Cold CMBHC1826LF CMBHC1826LC Low Profile with Security Package Hot Only CMBH1826LSP Hot Cold CMBHC1826LSP Tall Profile Hot Only CMBH1826TSF CMBH1826TBF CMBH1826TSC CMBH1826TBC Hot Cold CMBHC1826TSF CMBHC1826TBF CMBHC1826TSC CMBHC1826TBC Tall Profile with Security Package Hot Only CMBH1826TSP Hot Cold CMBHC1826TSP LOW PROFILE ONLY TALL LOW PROFILE TALL PROFILE ONLY ...

Page 2: ...properly grounded power source Use only manufacturer authorized power cord and replacement parts Warning Do not use this equipment in wet or damp conditions Warning Unplug unit prior to cleaning or service Warning Remove power cord from heater prior to cleaning Clean with damp cloth only Warning Do not submerge heater in water and never spray water on or near it Warning Do not get the thermometer ...

Page 3: ...anels Hot Only Models Located on the upper section of the TE unit mounted to the back of the cabinet On Off Power Switch Temperature set point digital controller Hot temperature is factory pre set to 165 F 73 9 C Hot Range 80 F to 170 F 26 7 C to 76 7 C Cold Temperature Control Hot Temperature Control Mode Switch for Cold or Hot Digital LED Display shows set point and temperature Digital LED Displ...

Page 4: ...ction IV B for recommended recovery times and holding times with the cart unplugged B HOT Only Camtherm Cart Maximizing Performance NOTE For maximum holding performance and to ensure safe food temperatures pre heat the cabinet at least 1 hour at the required temperature before loading with hot food MAX 170 F 76 7 C Refer to reference charts in section IV B for exact time guidelines 1 Press the pow...

Page 5: ...L PROFILE Includes 12 rail sets SHEET PANS 22 18 x 26 45 7 x 66 cm FULL SIZE FOOD PANS 12 x 20 32 5 x 53 cm 24 21 2 6 5 cm Deep 16 4 10 cm Deep 12 6 15 cm Deep 8 8 20 cm Deep Requires ten additional rail sets HOLDING CAPACITY LOW PROFILE Includes 6 rail sets SHEET PANS 11 18 x 26 45 7 x 66 cm FULL SIZE FOOD PANS 12 x 20 32 5 x 53 cm 12 21 2 6 5 cm Deep 8 4 10 cm Deep 6 6 15 cm Deep 4 8 20 cm Deep ...

Page 6: ... soft plastic brush CAUTION DO NOT USE A METAL BRUSH CAUTION DO NOT STEAM CLEAN OR DIRECT ANY WATER SPRAY INTO THE LOUVERS OR ANY OTHER OPENINGS AS SEVERE DAMAGE OR ELECTRICAL HAZARD COULD RESULT CAUTION AT NO TIME SHOULD THE CABINET BE WASHED OR FLOODED WITH WATER AS SEVERE DAMAGE OR ELECTRICAL HAZARD COULD RESULT IN INJURY AND DAMAGES Fig 1 Fig 2 ii Cleaning the Outside 1 Wipe down the external ...

Page 7: ...mode or on a Hot only TE unit is the temperature set point at the desired set temperature 4 On the Hot Cold TE unit has the mode switch been pressed until the desired Mode is illuminated 5 External fans Hot Cold only must operate to ensure module assemblies proper operation Loss of these fans can cause the modules to overheat and fail Make sure all of the external fans are operating Replace any fa...

Page 8: ... and void including any responsibility for damage costs and legal actions resulting from use or installation of product s in any non commercial setting 7 Adjustments such as calibrations leveling tightening of fasteners or utility connections normally associated with the original installation are the responsibility of the dealer or installer and not that of Cambro Manufacturing Improper installati...

Reviews: