4
1.0 OPERATION
1.1 Key Functions:
ZERO
Brings the scale to a zero balance reading. If the
ZERO
key
is pressed and held for 5 seconds the Calibration zero value
will be displayed.
GRS/NET
Toggles the display between Gross weight and Net weight.
This key is also used to enter Setup & Calibration Mode.
To enter, press and hold this key until the Parameter (
P xxx
)
Event counter is displayed, then release. Immediately after
CodE
is displayed, enter in sequence (within 5 seconds)
TARE
,
lb/kg
,
GRS/NET
, and
PRINT/ENTER
. The display will
indicate
ScAlE
and you are now in Setup & Calibration mode.
Note: P xxx and C xxx are event counters that will
increment each time one or more changes are made
to the Scale or Calibration Parameters.
TARE
Enters the Gross weight value into the Tare display and switches
to the net display mode. If the
TARE
key is pressed and held for 5
seconds the current Tare value will be displayed.
Lb/kg
Toggles the display between pounds and kilograms.
1.2 Error Messages:
ScnEg
When the weight is more than 10 divisions negative from the zero
calibration point.
OLD
The scale is in an overload condition.
BAtLo
Will flash when the battery voltage falls to 10.8VDC and will be
displayed constantly when the voltage falls to 10.2VDC.
Err d
More than 5000 scale divisions have been selected in
S1
Ntep or
S1
Angle mode. More than 20,000 scale divisions have been selected in
S1
No Mode.
Summary of Contents for CSW-15AT