Task 4: Configuring General and Unit
settings
Chapter 2: Configuration and alignment
2-52
pmp-0050 (May 2012)
Table 25
SM Unit Settings attributes
Attribute
Meaning
Set to Factory Defaults Upon
Default Plug Detection
If
Enabled
is checked, then an override/default plug functions
as a default plug. When the module is rebooted with the plug
inserted, it can be accessed at the IP address 169.254.1.1 and
no password, and all parameter values are reset to defaults.
A subscriber, technician, or other person who gains physical
access to the module and uses an override/default plug
cannot
see or learn the settings that were previously configured in it.
When the module is later rebooted with no plug inserted, the
module uses the new values for any parameters that were
changed and the default values for any that were not.
If
Disabled
is checked, then an override/default plug
functions as an override plug. When the module is rebooted
with the plug inserted, it can be accessed at the IP address
169.254.1.1 and no password, and all previously configured
parameter values remain and are displayed. A subscriber,
technician, or other person who gains physical access to the
module and uses an override/default plug
can
see and learn
the settings. When the module is later rebooted with no plug
inserted, the module uses the new values for any parameters
that were changed and the previous values for any that were
not.
See
Overriding Forgotten IP Addresses or Passwords on AP
on Page
Undo Unit-Wide Saved
Changes
When you click this button, any changes that you made in
any tab but did not commit by a reboot of the module are
undone.
Set to Factory Defaults
When you click this button,
all configurable parameters on all
tabs
are reset to the factory settings.