Before you begin

 

 

Introductory NOTES

 

This  operating  manual  includes  notations  and  symbols  that  make  it  easier  for  you  to  read  this 

document  and  which  are  intended  to  ensure  that  you  are  able  to  work  safely  with  Calyxo  solar 

modules.

 

 
 

 

SYMBOLS FOR SAFETY INSTRUCTIONS

 

 

Possible danger, injuries or damage 

Warning: dangerous electrical voltages 

Important information

 

2.1

 

Product features

 

 

PROPER 

U

SE

 

Calyxo solar modules are used to generate electrical power in photovoltaic systems. To generate power, 

the solar modules are attached to connectors and electrically connected to a control device such as an 

inverter or a charge controller.

 

 

Calyxo solar modules are developed and constructed in keeping with the latest technological 

developments. When used properly, in accordance with all of the instructions outlined in this operating 

manual and in combination with regular maintenance, they guarantee the highest level of safety.

 

 

The operator is responsible for full compliance with the instructions for mounting, transporting, wiring, 

storing, operating, cleaning and maintaining Calyxo solar modules outlined in this operating manual.

 

Any usage of Calyxo solar modules other than that described in this operating 

manual is prohibited. Calyxo shall assume no liability for damage to or caused by 

solar modules resulting from improper use.

 

Summary of Contents for CX1

Page 1: ...OPERATING MANUAL CX SERIES REV2 0 May 2017 EN EU USA Canada...

Page 2: ...S 7 4 MECHANICAL SPECIFICATIONANDDRAWING 10 5 ELECTRICAL SPECIFICATION 11 6 INSTALLATION 12 6 1 MOUNTING 12 6 2 MOUNTING VARIANTS 14 6 3 INSTALLATION SITE MODULE ORIENTATION 15 6 4 AVOIDINGSHADE 16 6...

Page 3: ...all the following requirements and instructions in order to be able to make full use of the performance capacity of Calyxo solar modules Ensure that the installation operational and maintenance work i...

Page 4: ...cted to a control device such as an inverter or a chargecontroller Calyxo solar modules are developed and constructed in keeping with the latest technological developments When used properly in accord...

Page 5: ...ion Physically disconnecting a closed electrical circuit could cause electrical voltage and currents such as electric arcs to arise These could result in life threatening injuries The risk increases w...

Page 6: ...concentrators such as mirrors or lenses or any other means to artificially concentrate light to increase the power output of the modules Doing so can damage the modules and shall render the extended w...

Page 7: ...key to safely handling glass is correctly selecting and using personal protective equipment Always ensure your own safety and wear safety goggles safety shoes and cut resistant gloves Gauntlet gloves...

Page 8: ...revention at constructionsites If you intend to install the modules on a rooftop or at a height observe the specialist regulations set out by the roofing trade Ensure proper fall protection since fall...

Page 9: ...uest documentation an acceptance report and an inspection report for the PV system with the minimum requirements set out by IEC DIN EN 62446 or VDE 0126 23 from the installer Store these reports toget...

Page 10: ...iew CX3pro Figure 3 Rear side view CX1 Figure 4 Front side view A CX3 9 0 mm CX3pro 7 0 mm CX1 9 0 mm CX4 7 0 mm Specification CX1 CX3 CX3pro CX4 Length 1200 mm Width 600 mm Weight 12 kg Structure Gla...

Page 11: ...t Current I sc A 10 Open Circuit Voltage V oc V 10 Current at Maximum Power I mp A 10 Voltage at MaximumPower V mp V 10 Maximum System Voltage 1000V IEC 600V UL Design Load 2400Pa IEC 50lb ft UL STC 1...

Page 12: ...ditions irradiance of 100 mW cm2 AM 1 5 spectrum and a cell temperature of 25 C 77 F TECHNICAL DATA Additional data including details of the electrical characteristics for the CX series power classes...

Page 13: ...cture that corresponds to the required statics and the local wind snowloads that can be properly fastened in the ground on the roof or on the facade that can transfer forces on the modules to the asse...

Page 14: ...lication The recommended minimum standoff height is 3 25 in 82 55 mm Modules used in UL Listed rooftop applications must be installed with approved mounting systems If alternate mounting means are emp...

Page 15: ...that no direct contact is made between glass and metal Use a suitable silicone free rubber support between the modules andclamps Clamp width figures 7 to 8 70 0 mm A minimum lateral distance between...

Page 16: ...ny point THEFOLLOWINGMOUNTINGVARIANTSARE POSSIBLE Substructure lateral beneath the module with two clamps per module side figure 7 Substructure diagonal beneath the longer sides with two clamps per mo...

Page 17: ...is only splash proof Solar modules are not explosion proof equipment Do not install the modules in the proximity of highly flammable gases and vapors such as gas containers petrol stations or near ope...

Page 18: ...angles of inclination less than3 longitudinal side of the module from the eave it needs to be ensured that adherent contamination is removed by sufficient precipitation or through regular manual clean...

Page 19: ...dry place The packaging is not weather resistant Ensure that even at low temperatures and or solar radiation of over 1000 W m the maximum open circuit voltage of the wired modules does not exceed the...

Page 20: ...a module the multiplying factor at conditions of an irradiance of 125 mW cm2 AM 1 5 spectrum and a cell temperature of minus 10 C plus 14 F for VOC and plus 75 C 167 F for ISC is to be determined and...

Page 21: ...rotected against reverse currents from the rest of the system with a string diode Within the scope of DIN VDE 0100 712 2016 10 diodes are no longer permitted as reverse currentprotection Usually each...

Page 22: ...ed with the module Install functional grounding for the solar power system when you are installing it in a country or a system in which functional grounding is necessary orprescribed Direct grounding...

Page 23: ...pro CX4 MC4 connectors of part numbers PV KST4 PV KBT4 CX1 feature MC3 connectors of part numbers PV KST3 PV KBT3 Please note the following when selecting connecting cables and connectors Only use pr...

Page 24: ...otected from dirt and moisture The connectors are not lying on a water collecting surface and are firmly connected toone another All necessary security and functional inspections have been carried out...

Page 25: ...te evening Do not wear any conductive pieces or clothing Never enter the installation area alone and without protection We recommend commissioning a specialist company with this work Ask your installe...

Page 26: ...om the top of the module in the following sequence Rinse off coarse soiling dust foliage etc from the modules with lukewarmwater Moisten stubborn soiling and carefully removeit Use lukewarm water and...

Page 27: ...cle and environmentally sustainable disposal of electrical and electronic devices is to be understood as a special law under the scope of the general German waste legislation which is laid out in the...

Page 28: ...information is always accessible and corresponds to the latest status However Calyxo assumes no responsibility for its use or for injuries to patentsor the rights of third parties that may result from...

Page 29: ...11 Notes...

Reviews: