Ethernet
Module Check
OR
Remote Alarm
Module Check
OR
A final module screen is displayed showing which specific modules were initialized.
The controller then displays the lamp optimization screen for 60 seconds to allow the lamp to
reach its optimum output. Finally, a final “start-up complete” screen is displayed. The system will
now be ready to disinfect water flow.
all detected modules
lamp reaching max output
successful start-up
Operational Screens (standard product)
On systems without the UV monitor, the default screen shows the
CalUltra Home Screen
. At
any point during operation the user is able to scroll through the
CalUltra Home Screen, Lamp
life remaining
,
QR Code, Contact Info and Maintenance Parts
screens by pressing the button
located on the front of the controller.
Operati
onal Screens (with UV monitor)
On systems with the UV monitor, the system will display the same screens as on the un-monitored
version except the UV Intensity replaces the home screen. The UV Intensity screen displays the
level of UV light detected by the sensor. UV intensity can be affected by poor water quality,
scaling on the quartz sleeve and/or sensor, lamp failure or lamp expiring. The following screens
show the UV Intensity dropping.