Calpeda NM Series Operating Instructions Manual Download Page 7

GB

NM-NMD Rev22 - Operating Instructions

Page 

7

12. TROUBLESHOOTING

OFF

   WARNING: Turn off the power supply before performing any operations.

 Do not allow the pump or motor to run  when dry even for a short period.

 Strictly follow the user instructions and if necessary contact an authorised service centre.

PROBLEM

PROBABLE CAUSES

POSSIBLE REMEDIES

1)

The motor does 

not start

1a) Unsuitable power supply

1b) Incorrect electrical connections 

1c) Engine overload protective device cuts 

in.

1d) Blown or defective fuses

1e) Shaft blocked

1f) If  the  above  causes  have  already 

been    checked,  the  engine  may  be 

malfunctioning

1a)  Check  that  the  mains  frequency    and  voltage  correspond  to  the 

electrical characteristics shown on the indicator plate

1b) Connect the power supply cable to the terminal board correctly. Check 

that the thermal overload protection is  set correctly (see data on the 

engine indicator plate) and make sure that the fuseboard upline of the 

engine has been properly connected

1c)  Check the power supply  and make sure that the pump shaft is turning 

freely.  Check  that  the  thermal  overload  protection  has  been  set 

correctly (see engine indicator plate)

1d) Replace the fuses, check the electric power supply and points a) and  c)

1e)  Remove the cause of blockage as indicated in the “Blocked  pump” 

instruction booklet

1f)  Repair    or  replace  the  engine  by  applying  to  an  authorised  service 

centre

2) 

Pump blocked

2a)  Prolonged  periods  of  inactivity  with 

formation of rust inside the pump

2b) Presence of solid bodies in the pump 

rotor

2c) Bearings siezed

2a)  Rotation  may  be  started  directly  from    the  pump  shaft  or  from  the 

joint (remember to turn off the electricity supply first ) or contact an 

authorised service centre 

2b) If possible, dismantle the pump casing  and remove any solid foreign 

bodies  inside  the  rotor,    if  necessary  contact  an  authorised  service 

centre 

2c)  If the bearings are damaged replace them or if necessary contact an 

authorised service centre 

3) 

The pump 

functions  

but no water 

comes out 

3a)  Possible infiltration of air from suction 

tube connections, drain plugs or filling 

of  pump  or  from  the  gaskets  of  the 

suction pipe

3b)  Foot valve  blocked  or suction pipe not 

fully immersed in liquid 

3c) Suction filter blocked

3a) Check which part is not  tight and seal  the connection adequately  

3b) Clean or replace the bottom valve and use a suction pipe suitable for 

the application 

3c) Clean the filter, if necessary, replace it . See point 2a) also.

4) 

Insufficient flow

4a)  Pipes  and  accessories  with  diameter 

too  small  causing  excessive  loss  of 

head 

4b) Presence of deposits or solid bodies in 

the internal passages of the rotor 

4c) Rotor deteriorated 

4d) Worn rotor and pump case

4e) Excessive  viscosity  of  the  liquid 

pumped  (if other than water) 

4f) Incorrect direction of rotation 

4g) Suction  head  excessive  in  relation  to 

the  suction capacity of pump 

4h) Suction pipe too long 

4a) Use pipes and accessories suitable for the specific application 

4b) Clean  the  rotor  and  install  a  suction  filter  to  prevent  other  foreign 

bodies from entering 

4c) Replace the rotor, if necessary, contact an authorised service centre 

4d) Replace the rotor and the pump casing 

4e) The pump is unsuitable 

4f) Invert the electrical connections on the terminal board  or control panel 

4g) Try to close the feeder gate partially and/or reduce the difference in 

level of the pump and the liquid being aspirated 

4h) Bring the pump closer to the suction tank so as to use a shorter pipe. 

If necessary use a pipe of a wider diameter 

5) 

Noise and 

vibrations 

from the pump

5a) Rotating part unbalanced 

5b) Worn bearings 

5c) Pump and pipes not firmly attached 

5d) Flow too strong for the diameter of the 

delivery pipe 

5e) Functioning in cavitation 

5f) Unbalanced power supply 

5g) Incorrect alignment of pump-motor unit

5a) Check that no solid bodies are obstructing the rotor 

5b) Replace the bearings 

5c) Anchor the delivery and suction piping as needed 

5d) Use bigger diameters or reduce the pump flow

5e) Reduce the flow by adjusting the feeder gate  and/or using pipes with 

a bigger internal diameter. See point 4g) too

5f) Check that the mains voltage is right

5g) If necessary, the unit must be re-aligned

6)  

Leakage from 

the mechanical 

seal

6a)  The  mechanical  seal  has  functioned 

when dry or has stuck 

6b) Mechanical  seal  scored  by  presence 

of abrasive parts in the liquid pumped 

6c) Mechanical  seal  unsuitable  for  the 

type of application 

6d) Slight initial drip during filling  or on first 

start-up

In  cases  6a),  6b)  and  6c),  replace  the  seal,  if  necessary  contact  an 

authorised service centre 

6a) Make sure that the pump casing  (and the suction pipe if the pump is 

not  self-priming) are full of liquid and that all the air has been expelled. 

See point 5 e) too. 

6b) Install a suction filter  and use a seal suited to the characteristics of the 

liquid being pumped. 

6c) Choose a seal with characteristics suitable for the specific application 

6d) Wait  for  the  seal  to  adjust  to  the  rotation  of  the  shaft.  If  the  problem 

persists, see points 6a), 6b) or 6c) or contact an authorised service centre.

Summary of Contents for NM Series

Page 1: ...Page English P gina Espa ol Close coupled pumps with threaded ports Bombas monobloc con bocas roscadas NM NMD C OPERATING INSTRUCTIONS INSTRUCCIONES DE USO...

Page 2: ...d chapter 6 5 1 1 Symbols To improve the understanding of the manual below are indicated the symbols used with the related meaning Information and warnings that must be observed otherwise there is a r...

Page 3: ...paragraph 2 1 Improper use of the device is forbidden as is use under conditions other than those indicated in these instructions Improper use of the product reduces the safety and the efficiency of t...

Page 4: ...site dimensions The customer has to prepare the installation site in order to guarantee the right installation and in order to fulfill the device requirements electrical supply etc The place where the...

Page 5: ...suction head which is too low less than 1 m to open the non return valve fill the pump through the priming hole par 12 3 fig 3 When the liquid level on the suction side is above the pump inflow under...

Page 6: ...ving the screws 20 12 9 DISPOSAL OFF The final disposal of the device must be done by specialized company Make sure the specialized company follows the classification of the material parts for the sep...

Page 7: ...ary replace it See point 2a also 4 Insufficient flow 4a Pipes and accessories with diameter too small causing excessive loss of head 4b Presence of deposits or solid bodies in the internal passages of...

Page 8: ...tilizan los s mbolos pictogramas a continuaci n con sus significados Informaci n y advertencias que deben respetarse si no causan da os al aparato o ponen en peligro la seguridad del personal Informac...

Page 9: ...y fabricado exclusivamente para el uso descrito en el p r 2 1 Est totalmente prohibida la utilizaci n del dispositivo para usos impropios y que no est n indicados en este manual El uso impropio del p...

Page 10: ...ro material que podr a da ar la bomba Si el peso supera los 25 Kg el embalado tiene que ser levantado por dos personas al mismo tiempo 6 INSTALACI N 6 1 Dimensiones Para las dimensiones del aparato v...

Page 11: ...ue La bomba no debe funcionar en presencia de parte deteriorada 7 2 Primer arranque OFF ATENCI N Evitar absolutamente el funcionamiento de la bomba en seco Poner la bomba en marcha nicamente despu s d...

Page 12: ...n las bombas NM C sacando los tornillos 14 24 se extrae el motor completo con el rotor sin mover el cuerpo bomba de la tuber a Con la bomba NMD hay que extraer tambi n el cuerpo de la bomba cuerpo asp...

Page 13: ...aci n c Limpiar el filtro si es necesario sustituirlo Ver tambi n el punto 2a 4 Caudal insuficiente a Tuber a y accesorios con di metro demasiado peque o que provocan excesivas perdidas de carga b Pre...

Page 14: ...Rev22 14 12 3 4 93 098 4 93 010 4 93 009 Fig 1 Positive suction head operation Funcionamiento bajo carga Fig 3 Filling Llenado Fig 4 Scarico Vaciado Fig 2 Suction lift operation Funcionamiento en aspi...

Page 15: ...087 81 00 82 08 82 00 76 00 76 16 73 00 36 50 78 00 70 00 46 00 18 00 28 00 16 00 20 12 82 04 88 04 16 05 28 04 90 04 98 00 98 08 76 04 76 54 70 20 28 20 98 04 70 18 36 00 30 00 20 00 20 04 16 20 88 0...

Page 16: ...28 00 14 12 14 12 28 00 28 20 14 24 32 00 36 00 46 00 73 00 78 00 81 00 82 04 82 00 92 00 88 00 14 00 28 04 14 04 14 20 70 18 70 00 76 54 76 04 98 00 94 00 94 02 98 04 76 50 90 00 76 00 90 04 3 94 05...

Page 17: ...C 2009 125 EC 2014 30 EU 2014 35 EU and assume full responsability for conformity with the standards laid down therein Commission Regulation No 547 2012 640 2009 DECLARACION DE CONFORMIDAD En CALPEDA...

Reviews: