GB
I-MAT_Ed2 - Operating Instructions
Page 39 / 136
16.1. Parameters UP – user parameters
N°
Description
Values
Standard Modification
UP01
Restart mode power failure
rA = automatic
rM = manual
rA
UP02
Nominal pump current
(A)
s.m.
UP03
Nominal pump frequency
(Hz)
50
UP04
Direction of rotation
E---
UP05
Operating mode
PC = Constant pressure
PP = Proportional pressure
tC = Constant temperature
CF = Constant flow rate
Man = Fixed speed
PC
UP06
Primary set-point
1,5
UP07
Secondary set-point
1,5
16.2. Parameter AP – Advanced parameters
N°
Description
Values
Standard Modification
AP01
Maximum pump pressure
(bar)
0
AP02
Primary transducer supply
1 = 0-10V
2 = 4-20mA
3 = 0-20mA
2
AP03
Primary transducer measuring unit
1 = bar
2 = m3/h
3 = Hz
4 = °C
1
AP04
Primary transducer minimum value
0
AP05
Primary transducer maximum value
10
AP06
Secondary transducer supply
1 = 0-10V
2 = 4-20mA
3 = 0-20mA
2
AP07
Secondary transducer measuring unit
1 = bar
2 = m3/h
3 = Hz
4 = °C
1
AP08
Secondary transducer minimum value
0
AP09
Secondary transducer maximum value
10
AP10
Secondary transducer mode
Off
DiFF = Differential mode
nMOd = Night mode
REM = Remote control
Off
AP11
Cascade mode
Off
UU = Cascade 2-6 converters
UF = Single converter
cascade
dP = Twin pump
Off
AP12
Master/Slave setting
MAS = master
SLA = slave
SLA
AP13
Pump address
SLA1÷SLA5
SLA1
AP14
Rump-up
(s)
3
AP15
Rump down
(s)
3
AP16
Stand-by mode setting
Off
FM = minimum frequency
PrP = pre-pause frequency
Off
AP17
Frequency before stop and minimum run
frequency automatic calculation
Auto = automatic
Man = manual
Auto
AP18
Night mode enable
On, Off
Off
AP19
Night mode activation
(°C)
20
AP20
Night mode activation time
(min)
60
AP21
Night mode disable threshold
(°C)
20
AP22
Dry-run time
(s)
10
AP23
First dry-run time
(s)
60
AP24
Dry-run pressure
(bar)
1,5
AP25
Periodically start system activation time
(Ore)
0
AP26
Periodically start system frequency
(Hz)
40
AP27
Periodically start system operating time
(min)
1
AP28
System leakage control
On,Off
Off
Summary of Contents for I-MAT 11.2TT-B
Page 17: ...IT I MAT_Ed2 Istruzioni originali Pagina 17 136 16 Elenco parametri di programmazione...
Page 38: ...GB Page 38 136 I MAT_Ed2 Operating Instructions 16 Parameter table list...
Page 59: ...D I MAT_Ed2 Betriebsanleitung Seite 59 136 16 Verzeichnis Programmierungsparameter...
Page 101: ...E I MAT_Ed2 Instrucciones de uso P gina 101 136 16 Lista par metros de programaci n...
Page 109: ...RU I MAT_Ed2 C 109 136 3 4 3 5 ENTER 3 6 20 3 7 3 8 5 19 30 50 50 30 60 60 0 30 30 0...
Page 110: ...RU C 110 136 I MAT_Ed2 4 4 1 10 4 2 4 3 4 4 5 X 5 1 25 X 6 6 1 i 6 2 20 1 1 6 3 20 1 2...
Page 122: ...RU C 122 136 I MAT_Ed2 16...