GB
A,AS Rev13 - Operating Instructions
Page 9 / 64
1.5. Technical assistance
Any further information about the documentation,
technical assistance and spare parts, shall be
requested from: Calpeda S.p.A. (paragraph 1.2).
2. TECHNICAL DESCRIPTION
Close-coupled centrifugal pumps with open
impeller.
The built-in backflow preventer avoids reverse
siphoning when the pump is stopped and assures
automatic re-priming at the next start.
The pump re-primes itself even if partially filled with
liquid and with completely empty suction pipe.
A: version with pump casing and lantern bracket in
cast iron.
B-A: version with pump casing and lantern bracket
in bronze
(the pumps are supplied fully painted).
2.1. Intended use
- For clean or slightly dirty water, also with solids
up to 10 mm grain size (15 mm for A 65-150 and
A 80-170),
- Liquid temperature from -10 °C to +90 °C.
2.2. Improper use
The device is designed and built only for the
purpose described in paragraph 2.1.
Improper use of the device is forbidden, as
is use under conditions other than those
indicated in these instructions.
Improper use of the product reduces the safety and
the efficiency of the device, Calpeda shall not be
responsible for failure or accident due to improper
use.
Do not use in ponds, tanks or swimming
pools or where people may enter or come
into contact with the water.
2.3. Marking
The following picture is a copy of the name-plate
(see Pic.1) that is on the external case of the pump.
1 Type 1
2 Delivery
3 Head
4 Rated power
5 Supply voltage
6 Fréquence
7 Nom. motor current
8 Rotation speed rpm
9 Operation Duty
10 Insul. class
11 Certifications
12 Serial number
13 Weight
14 Notes
15 Voltage
16 % Load
17 Power factor
18 Efficiency
19 Protection
20 Efficiency Class
Example plate pump
Made in Italy
MONTORSO
A 65-150B/B
IE2-87
0705158995
H max/min 21,5/6,5 m
n 2900/min
XYXYRRY
IEC 60034-1
3kW (4Hp)
VICENZA
Made in Italy
MONTORSO
Q min/max 15/54 m
3
/h
0705158995
IP 54
n 2900/min
230∆/400Y V3~50Hz
%
100
75
50
cos
ϕ
0,78
0,71
0,58
η
87,5
88,1
85,4
V
400
400
400
11,5 / 6,6 A
S1 l.cl. F
S1 49kg
92kg
3kW (4Hp)
VICENZA
1
11
2
3
4
4
5
6
7
8
9
10
12
13
19
20
8
9
13
14
15
16
17
18
Example plate pump
Made in Italy
MONTORSO
A 65-150B/B
IE2-87
0705158995
H max/min 21,5/6,5 m
n 2900/min
XYXYRRY
IEC 60034-1
3kW (4Hp)
VICENZA
Made in Italy
MONTORSO
Q min/max 15/54 m
3
/h
0705158995
IP 54
n 2900/min
230∆/400Y V3~50Hz
%
100
75
50
cos
ϕ
0,78
0,71
0,58
η
87,5
88,1
85,4
V
400
400
400
11,5 / 6,6 A
S1 l.cl. F
S1 49kg
92kg
3kW (4Hp)
VICENZA
1
11
2
3
4
4
5
6
7
8
9
10
12
13
19
20
8
9
13
14
15
16
17
18
3. TECHNICAL FEATURES
3.1. Technical data
Dimensions and weight (see technical catalogue).
Nominal speed 2900/3450 rpm
Protection IP54
Supply voltage / Frequency
230 V1~50 Hz
220 V1~60 Hz
230/400 - 400/690 V3~50 Hz
220/380 - 380/660 V3~60 Hz
The electric data marked on the label are referred
to the nominal power of the motor.
Sound pressure: - A 40-110: ≤ 67 dB (A).
- A 50-125: ≤ 75 dB (A).
- A 65-150: ≤ 83 dB (A).
- A 80-170: ≤ 83 dB (A).
Max. starts per hour: 40 at regular intervals.
Maximum permissible working pressure up to 6 bar
(10 bar for A 80-170).
3.2. Operating conditions
Installation in well ventilated location protected from
the weather, with a maximum ambient temperature
of 40 °C.
4. SAFETY
4.1. General provisions
Before using the product it is necessary to
know all the safety indications.
Carefully read all operating instructions and the
indications defined for the different steps: from
transportation to disposal.
The specialized technicians must carefully comply
with all applicable standards and laws, including
local regulations of the country where the pump is
sold.
The device has been built in conformity with
the current safety laws. The improper use could
damage people, animals and objects.
The manufacturer declines any liability in the event
of damage due to improper use or use under
conditions other than those indicated on the name-
plate and in these instructions.
i
Follow the routine maintenance schedules
and the promptly replace damaged parts,
this will allows the device to work in the best
conditions.
Use only original spare parts provided from Calpeda
S.p.A or from an authorized distributor.
Don’t remove or change the labels placed
on the device.
Do not start the device in case of defects or
damaged parts.
Maintenance operations, requiring full or
partial disassembly of the device, must
be done only after disconnection from the
supply.
A,AS Rev13.indd 9