Installation Instructions
Cable from Power Supply
Green Wire
(Grounding)
Junction Box
Black Wire
White Wire
Cable from appliance
The Caloric Induction Cooktops must connect to a separate, grounded
three-wire, single phase, AC Only electrical supply with their own circuit
breaker. These appliances must be installed in accordance with National
Electrical Codes, as well as all state, municipal and local codes. This
appliance must be supplied with the proper voltage and frequency and
amperage, which is protected by a properly sized circuit breaker or time
delay fuse.
Electrical ground is required on this appliance
WARNING
The cooktop conduit wiring is approved for copper wire
connection only, if you have aluminum house wiring, use only special
connectors which are approved for joining copper and aluminum wires
conform with local codes and ordinances. Follow the electrical connector
manufacturer’s recommended procedure closely.
19
Red Wire