18 /EN
•
The air tube installation must not be omitted for the cold-water inlet, and we
recommend installing one for the hot water outlet also.
•
The air tube discharge must be slightly higher than the upper level of the cistern, by
at least 20 cm
(See Fig.3).
•
Long segments of piping should be avoided and/or accessories such as elbows,
T connections, distributing valves, etc. (The recommended distance between the
heater and the point of use should not exceed 5 m).
•
To have the correct hot water pressure, the cistern must be at least 2 m above the
shower level.
IMPORTANT
In the open system, DO NOT INSTALL the included relief valve, because it could cause a
loss of line pressure.
Closed or Pressurized System (direct from the water network system):
(regarding the
heater’s water supply, we recommend installing a relief valve (NOT INCLUDED) at the hot
water outlet, calibrated at (0,68 MPa) (7 kgf/cm
2
) (100 psi).
IMPORTANT
When there is excessive pressure, water exits through the relief valve. This is a normal
mechanism and does not mean the heater has a failure. Avoid undue water spills by
installing a drainage tube at the relief valve exit towards the drains.
Maximum operating pressure of 0,7 MPa (7,13 kgf/cm
2
)
We recommend checking the relief valve (included) at least once a year, to make sure it
is in good working condition.
Open System Installation Diagram
Tinaco
Entrada de agua fría
Salida de agua caliente
20 cm
Como mínimo
Jarro de aire
Jarro de aire
Válvula de drenado
(no incluida)
Adaptadores NPT
(incluidos)
Tuercas Unión
(no incluidas)
Válvula de paso de agua
(no incluida)
Al drenaje abierto
Nunca conecte esta salida a
su sistema de plomería
FIG. 3