17 /EN
•
Make two horizontal drill holes with a
½
” concrete bit at a distance of 240
mm
(See Fig. 2).
•
Generally, for different wall types, especially walls with bricks, perforated
blocks, or blocks with limited firmness, this mounting must be checked for
safety. The wall mounting hooks must be able to support a weight three
times the weight of the heater full of water.
•
Do not place objects under the water heater, to avoid damages.
Before connecting the device, you must:
•
Make sure that the product characteristics (refer to the data on the label located
on one side of the heater) comply with the requirements for its correct operation.
This appliance must be installed according to the following indications regarding the
presence of:
-
Humidity:
do not install the appliance in humid environments (without ventilation).
-
Ice:
do not install the appliance in environments with a probability of temperatures
dropping to critical levels with a risk of ice formation.
-
Sun rays:
do not expose the appliance directly to solar rays, not even through glass.
-
Dust/fumes/gases:
do not install the appliance in notably aggressive environments,
such as those with acid fumes, dusts, or saturated gas.
-
Electric shock:
do not install the appliance directly on power lines that are not protected
from voltage fluctuations.
V.- HYDRAULIC WATER INSTALLATION
To achieve a good heater installation, verify the type of water feed system you
have at your home, there are two different types.
Open system
(with a cistern): to supply water to the heater, an air tube must be
installed at the cold-water inlet.
FIG. 2
Perforationts with a
depth of 90 mm
Ø 1/2
5-6 mm
Anchor bolt
installation
requirements