background image

Page 16

Page 17

NB: Not to scale.

SPARE PARTS
(Refer to centre pages for location).

CBTCW

CBTSS

UTHSG

NB15GS

NB10GS

NB5GS

TN2CK

TAP CUP WASHER

TAP SPRING

TAP SLOTTED

STEM

GREY TAP BODY

HEAT SHIELD

GASKET SET FOR

MODEL 5L

SLOW FILL NOZZLE

17

18

19

20

24

23

22

21

CBTS

NB5BA

BODY FOR

MODEL 5L

25

NB15BA

NB10BA

BODY FOR

MODELS 7.5L & 10L

27

26

NB5BLG

BODY LID GASKET

FOR MODEL 5L

28

NB5WLCPT

NB15BLG

WATER LEVEL

CONTROL PIPE FOR 5L

31

30

NB7.5WLCPT

WATER LEVEL

CONTROL PIPE FOR 7.5L

32

NB10BLG

BODY LID GASKET FOR

MODELS 7.5L & 10L

29

GASKET SET FOR

MODELS 7.5L & 10L

GASKET SET FOR

MODEL 15L

BODY FOR

MODEL 15L

BODY LID GASKET

FOR MODEL 15L

X8

X8

X8

SPARE PARTS
(Refer to centre pages for location).

CASPCBT

NBPRG

NBE3HK

15PMFK

10PMFK

7.5PMFK

5PMFK

NBTSC40

NBSV

NBWPT

TAK

NBTLC40

NBMR

TBT

GTT

PRINTED CIRCUIT

BOARD Inc.TRIAC

LIGHT PCB

PRESSURE RELIEF

GROMMET

3kW ELEMENT

PLASTIC MOULDED

FASCIA KIT FOR 5L

WATER PIPE

Ø15mm SILICONE

TUBE CUT 40mm

Ø20mm SILICONE

TUBE CUT 40mm

MANUAL RESET

THERMAL CUTOUT

DRAW OFF TAP

BODY

TAP TOP

ASSEMBLY

1

2

3

4

8

7

6

5

9

10

11

12

16

15

14

13

COMLPCBA

PLASTIC MOULDED

FASCIA KIT FOR 7.5L

PLASTIC MOULDED

FASCIA KIT FOR 10L

PLASTIC MOULDED

FASCIA KIT FOR 15L

THERMISTOR

ASSEMBLY KIT

SOLENOID VALVE

X1

NB: Not to scale.

Summary of Contents for Clipper 2 5L

Page 1: ...Manuals and Documents Brought to you by Wechillit com Ltd WCI Group House 18 Pride Hill Shrewsbury SY1 1DQ Tel 01743 289418 Fax 01743 289416 Web www wechillit com...

Page 2: ...ERVICING INSTRUCTIONS Calomax Limited Lupton Avenue Leeds LS9 7DD Tel 0113 249 6681 Fax 0113 235 0358 e mail service calomax co uk www calomax co uk Please read these instructions carefully before ope...

Page 3: ...ions For assistance in nding a suitable engineer in your area visit our website www calomax co uk contact our service department on 0113 249 6681 or e mail service calomax co uk CHECK LIST Before comm...

Page 4: ...is not suitable for installation where a water jet could be used Install the boiler in a position having adequate ventilation on a wall capable of carrying the working weight of the boiler A suitably...

Page 5: ...issioning cycle and water is drawn from the tap water will be replaced in short cycles Small amount of water and then heat The solenoid and element will never be on at the same time unless the boiler...

Page 6: ...he solenoid coil through overheat To re energise the solenoid the unit must be disconnected from the electrical supply and then switched back on after rst reinstating the water supply If the unit requ...

Page 7: ...switching on the electrical supply to the boiler The printed circuit board PCB controls the heating and lling functions of the boiler by monitoring the thermistor and level sensors The PCB also contr...

Page 8: ...udes nuts washers etc Exploded parts view for Clipper Range boilers To be read in conjunction with the spare parts list 25 26 or 27 depending on model 1 2 3 4 5 9 10 11 12 13 13 14 15 17 19 18 16 21 2...

Page 9: ...outlet WMPDTK2 to suit 7 5L 10L WMPDTK3 to suit 15L Swivel Nozzle attachment Non swivel nozzles also available please contact Calomax for further information Ref SN made to customer s dimensions x y F...

Page 10: ...10L 29 GASKET SET FOR MODELS 7 5L 10L GASKET SET FOR MODEL 15L BODY FOR MODEL 15L BODY LID GASKET FOR MODEL 15L X8 X8 X8 SPARE PARTS Refer to centre pages for location CASPCBT NBPRG NBE3HK 15PMFK 10P...

Page 11: ...DENSER EARTH ON BACKPLATE EARTH CONNECTION FOR OUTER CASING WHITE SHEATHING LIGHT PCB TRANSPARENT LIGHT UPPER MOST IN FASCIA RCD INCOMING SINGLE PHASE SUPPLY THROUGH A DOUBLE POLE ISOLATING SWITCH FUS...

Page 12: ...e page 12 Faulty wiring to thermistors faulty thermistors Temperature controller needs adjusting Element failed to earth Defective Printed Circuit Board De scale the boiler Particularly thermistor Rep...

Page 13: ...base warranty Some factors are beyond our control and would invalidate the warranty offered These include Incorrect installation High Low water pressure Incorrect voltage supply Accidental damage Lime...

Page 14: ...nutes 60 Minutes Average Flow rate from tap Standard nozzle 2 5 Litres Minute Voltage 220 240 V ac 50 60 Hz Power rating 3kW MAX PLEASE ENTER MODEL AND SERIAL NUMBER FOR FUTURE REFERENCE Note All meas...

Reviews: