Page 8
Page 9
CLEANING
•
Hold a cup below the tap or place large vessels on the drip tray.
Care must be taken to avoid injury through splashing or over- lling.
•
To begin lling, pull the handle forward or push it backward – hot
water begins to ow. If the tap is opened fully it can be locked open
(for lling large vessels) in this state the boiler must never be left
unattended.
•
To stop lling, release the handle so it returns to the closed
position. NEVER PASS YOUR HAND BENEATH THE NOZZLE.
•
Please retain these instructions for future reference
•
Ensure that a suitable drip tray is positioned below the tap nozzle.
This will help keep the surrounding work surfaces and oor free
from drips or splashes. Various options are available and are
outlined on the Accessories page of this booklet.
•
All de-scaling and servicing must be performed by a suitably
quali ed engineer.
GENERAL NOTES
GENERAL OPERATION
Avoid using any abrasive materials. Wiping the outer casing
with a damp cloth should be suf cient. Some stainless
steel cleaning products may not be suitable for plastic and
must not come in contact with the plastic fascia. Always
disconnect the electrical supply before cleaning.
NEVER USE A SPRAY JET OR ANY OTHER METHOD WHICH COULD
CAUSE WATER TO ENTER THE ELECTRICAL CHAMBER.
When the green service indicator light on the front of the boiler is showing
solid colour, the machine has been starved of water for in excess of 20
minutes and the solenoid valve has been disabled to prevent damage to
the solenoid coil through overheat. To re-energise the solenoid, the unit
must be disconnected from the electrical supply and then switched back
on, after rst reinstating the water supply.
If the unit requires servicing the service indicator will ash a sequence
of light pulses. A 2x or 3x-light pulse generally indicates that the low or
normal level probes require de-scaling.
A 4x-light pulse means the water level has reached the high level sensor
and the likelihood is that the machine has over- lled due to debris trapped
in the solenoid valve. The debris can be removed by drawing plenty of
water from the dispense tap, causing the solenoid valve to operate and
ush out the obstruction. The machine will reset itself once the problem
has cleared. If this does not rectify the problem, turn off the water supply
and check for debris in the valve’s lter. The unit can be used normally
while the service indicator is ashing a 4x pulse. For further assistance,
contact our service department on 0113 249 6681
e-mail [email protected]. or nd a local service engineer at
www.calomax.co.uk
Once the outer casing is removed, access to the Service Area has
been gained. This access must be restricted to persons having
knowledge and practical experience of the appliance, in particular as
far as safety and hygiene are concerned.
De-scale
To gain access to internal components, the body lid must be removed. To
remove the lid, break the lid gasket seal and lift it clear of the body.
Note
: Whenever the body lid has been removed from the boiler a new lid
gasket may be required to ensure a steam-tight joint. Damage to the unit
caused by a poor lid seal is not covered by warranty.