background image

Page 4

Page 5

LOCATION

COLD WATER INLET

INSTALLATION

All metalic components of the machine, in direct contact with
drinking water are manufactured from high quality 304 grade
stainless steel, or non ferrous materials, providing maximum
resistance to corrosion.

CONSTRUCTION

The boiler must be installed in a location where access is
restricted to operators that are suitably trained, or where
untrained operators of the machine can be supervised by trained
personnel.

To comply with recommendations
from the health and safety executive
it is important that due consideration
be given to safe operation of the
controls of the boiler. The boiler
should therefore be mounted in
such a manner that the operator can
stand directly facing the machine
with the controls at a recommended
height from the oor to the draw-off
tap handle of /- 100mm.
Consideration should also be given

to the servicing requirements of the machine. The maximum and
minimum ambient operating conditions must be between 5 °C
and 35 °C. The appliance is not suitable for installation where
a water jet could be used. Install the boiler in a position having
adequate ventilation, on a wall capable of carrying the working
weight of the boiler. A suitably quali ed engineer must install this
unit. Plumbing and electrical installation work is involved.

To comply with the U.K. Water Supply Regulation a single check-
valve must be tted to the supply. BEFORE CONNECTING, THE
SUPPLY PIPE MUST BE THOROUGHLY FLUSHED OUT TO
ENSURE THAT FOREIGN MATTER DOES NOT BLOCK OR
ENTER THE SOLENOID VALVE

The boiler must be connected to a potable water supply, in a
manner which complies with UK water regulations. The boiler
should be connected to a ½” (15mm) drinking water supply via an
appropriate isolating valve. The supply must provide a constant
pressure of between 20 KPa and 1000 KPa (0.2 to 10 Bar)

.

If the water supply contains excessive solids in suspension it is
recommended that a ne mesh “in line” water lter is tted in the
pipe work. Failures due to scale and sediment are not covered by
the warranty.

MODEL

A

B

C

DRY

WEIGHT

WORKING

WEIGHT

5L

mm

510

313

226

10

Kg

17

Kg

7.5L

mm

582

368

251

13

Kg

24.5

Kg

10L

mm

582

368

251

13

Kg

27

Kg

15L

mm

623

401

274

15

Kg

35

Kg

DIMENSIONS AND WEIGHTS

B

A

C

Summary of Contents for Clipper 2 10L

Page 1: ...Manuals and Documents Brought to you by Wechillit com Ltd WCI Group House 18 Pride Hill Shrewsbury SY1 1DQ Tel 01743 289418 Fax 01743 289416 Web www wechillit com...

Page 2: ...ERVICING INSTRUCTIONS Calomax Limited Lupton Avenue Leeds LS9 7DD Tel 0113 249 6681 Fax 0113 235 0358 e mail service calomax co uk www calomax co uk Please read these instructions carefully before ope...

Page 3: ...ions For assistance in nding a suitable engineer in your area visit our website www calomax co uk contact our service department on 0113 249 6681 or e mail service calomax co uk CHECK LIST Before comm...

Page 4: ...is not suitable for installation where a water jet could be used Install the boiler in a position having adequate ventilation on a wall capable of carrying the working weight of the boiler A suitably...

Page 5: ...issioning cycle and water is drawn from the tap water will be replaced in short cycles Small amount of water and then heat The solenoid and element will never be on at the same time unless the boiler...

Page 6: ...he solenoid coil through overheat To re energise the solenoid the unit must be disconnected from the electrical supply and then switched back on after rst reinstating the water supply If the unit requ...

Page 7: ...switching on the electrical supply to the boiler The printed circuit board PCB controls the heating and lling functions of the boiler by monitoring the thermistor and level sensors The PCB also contr...

Page 8: ...udes nuts washers etc Exploded parts view for Clipper Range boilers To be read in conjunction with the spare parts list 25 26 or 27 depending on model 1 2 3 4 5 9 10 11 12 13 13 14 15 17 19 18 16 21 2...

Page 9: ...outlet WMPDTK2 to suit 7 5L 10L WMPDTK3 to suit 15L Swivel Nozzle attachment Non swivel nozzles also available please contact Calomax for further information Ref SN made to customer s dimensions x y F...

Page 10: ...10L 29 GASKET SET FOR MODELS 7 5L 10L GASKET SET FOR MODEL 15L BODY FOR MODEL 15L BODY LID GASKET FOR MODEL 15L X8 X8 X8 SPARE PARTS Refer to centre pages for location CASPCBT NBPRG NBE3HK 15PMFK 10P...

Page 11: ...DENSER EARTH ON BACKPLATE EARTH CONNECTION FOR OUTER CASING WHITE SHEATHING LIGHT PCB TRANSPARENT LIGHT UPPER MOST IN FASCIA RCD INCOMING SINGLE PHASE SUPPLY THROUGH A DOUBLE POLE ISOLATING SWITCH FUS...

Page 12: ...e page 12 Faulty wiring to thermistors faulty thermistors Temperature controller needs adjusting Element failed to earth Defective Printed Circuit Board De scale the boiler Particularly thermistor Rep...

Page 13: ...base warranty Some factors are beyond our control and would invalidate the warranty offered These include Incorrect installation High Low water pressure Incorrect voltage supply Accidental damage Lime...

Page 14: ...nutes 60 Minutes Average Flow rate from tap Standard nozzle 2 5 Litres Minute Voltage 220 240 V ac 50 60 Hz Power rating 3kW MAX PLEASE ENTER MODEL AND SERIAL NUMBER FOR FUTURE REFERENCE Note All meas...

Reviews: