Paragon-X Getting Started Guide

 

 

 

Page 13 of 28

 

 

Installing the Application Software  

The  Paragon-X  software  comprises  two  parts:  embedded  software  which  is  pre-installed  on  the 

Paragon-X hardware prior to delivery, and application software supplied on a USB memory stick (or 
by download fro

www.calnexsol.com

which requires installing on the host PC to allow control of 

Paragon-X. To install this application software: 

1.

 

Insert the USB stick into a USB port on the host PC. Depending on the PC configuration, Windows 
Explorer  may  launch  automatically.  If  it  does  not,  open  Windows  Explorer.  Browse  to  the  USB 
device,  double  click  the  setup.exe  file  then  follow  the  on-screen  instructions.  A  number  of 
applications will be installed in sequence. 

2.

 

Once the installation process is complete, click on Start > All Programs > Calnex > Paragon-
X
 to launch the Paragon-X Remote Client app as shown below (note that the path may be different 
if the settings were changed from default during the installation process):  

  

  

The  software  version  of  the  Paragon-X  application  can  be  found  by  clicking  on  Help  >  About 
Paragon Remote Client
.  

The  latest  release  software  is  available  from 

https://calnexsol.com/en/resources-en/product-

software

 (registration required). For information on how to upgrade your current capability or add 

new features, contact [email protected].  

3.

 

For full functionality, Wireshark should also be installed on the host PC. A version may be included 
on the installation USB stick provided with Paragon-X, or the latest version may be downloaded 
fro

www.wireshark.org

Once obtained, double click on the Wireshark***.exe file and follow the 

onscreen prompts. 

 

4.

 

It is possible to use the Paragon-X Remote Client app without being connected to an instrument. 
This  allows  existing  capture  and  replay  files  to  be  manipulated  without  requiring  access  to  the 
Paragon-X hardware, or, by clicking Help then Demo, a demo mode which uses pre-configured 
demo capture files to simulate measurements may be accessed. 

 

 

Summary of Contents for Paragon-X

Page 1: ...Paragon X Getting Started Guide Page 1 of 28...

Page 2: ...rmance or use of this material To prevent fire or shock hazard do not expose the unit to rain or moisture To avoid electrical shock Use only power cord supplied or one with adequate ratings and connec...

Page 3: ...eference Accessory 1pps ToD Frequency Converter Accessory Introduction For Next Gen technologies up to 10Gb s the Calnex Paragon X offers direct insight into actual device and service behaviour and th...

Page 4: ...nex Solutions by telephone 44 0 1506 671 416 or by email support calnexsol com Paragon X AC adaptor 1 Power cord 1 USB memory stick 1 Getting Started Guide 1 Rb GPS External Reference AC adaptor 1 Pow...

Page 5: ...D Frequency converter accessory to convert from high impedance single ended signal or RS 422 balanced signal Lower Front Aux Port earlier versions 10MHz Clock Out frequency locked to whatever referenc...

Page 6: ...ter is enabled and generating packets all cases except Master Test configuration The 1PPS output is locked to whatever Paragon X 1PPS reference is in use pin 3 ve and pin 6 GND Both outputs use an in...

Page 7: ...used for directly connecting Paragon X to a PC or laptop running Microsoft Windows 7 or Windows 10 OS the host PC Connection over a network is possible but not recommended see Calnex Application Note...

Page 8: ...ower Input 11 Power Switch 12 1PPS Reference Input 13 Wander Measurement Inputs 14 Reference Inputs 15 Reset Switch 16 64K AMI Reference Input 17 GPS Reference 18 GPS Antenna Input 10 DC Power Input F...

Page 9: ...64K AMI Reference Input For connection to 64kb s external system reference clock Pin 2 tip pin 6 ring pin 1 GND 17 GPS Reference An alternative to connector 12 accepts a 1PPS reference input signal on...

Page 10: ...n AC outlet 4 Use Paragon X s rear panel power switch marked I 0 to switch on Paragon X 5 The blue display on the front panel will turn on Paragon X is initialised and ready to use after approximately...

Page 11: ...gateway The IP address used should be different from the Paragon X IP address shown on its display only in the last 3 digits e g for a Paragon X IP address of 192 168 3 100 a suitable host PC IP addre...

Page 12: ...to Paragon X or run the associated software first confirm that these ports are available Paragon X remote client application ports 9990 and 9000 CAT and PFV ports 1337 and 1338 If Paragon X is connect...

Page 13: ...at the path may be different if the settings were changed from default during the installation process The software version of the Paragon X application can be found by clicking on Help About Paragon...

Page 14: ...o alarms red current alarm yellow historic alarm i e alarm has occurred within the current test duration grey not active in the current configuration Link indicates if there is a physical Ethernet con...

Page 15: ...any provide access to functions also available via workflow buttons and icon menu bar items allowing alternative methods for controlling Paragon X depending on user preference 6 Mode Title Bar Identif...

Page 16: ...modes will depend on the options fitted licenced on Paragon X CES Circuit Emulation Service for example CESoP SAToP TDMoIP Requires Option 202 1588v2 IEEE1588v2 advanced analysis features Enable Maste...

Page 17: ...se the dialog box 7 The Configure Capture workflow button may then be used to configure detailed settings for the selected measurements 8 Click on Setup Interface to configure the ethernet interfaces...

Page 18: ...filters for packet impairments and Set Capture for packet decode and measurement filter setting Note the Set impair option is only available in Master Slave Emulation mode when capturing on the Parago...

Page 19: ...aphic or use the Configure button to access manual settings Note that the displayed image will change depending on which type of test has been selected and so provides a convenient checkpoint for devi...

Page 20: ...test pre enabled for further information on any given metric including their meaning any relevant Standards and the maths used in their calculation select the icon beside its entry 9 The View Results...

Page 21: ...nd or the 10M Ref Output to the Paragon X 10MHz Reference Input rear panel connector The Rb GPS Frequency Reference has the following front and rear panel features Power On LED Rb Locked LED Track Syn...

Page 22: ...ial the GPS Antenna input is connected properly and safely to the GPS antenna The GPS antenna and associated cables require an EMP Protector to be fitted for safety reasons The EMP Protector should be...

Page 23: ...indicates that the equipment should only be disposed of through an approved method At the end of life please dispose of the equipment through a recognized and approved scheme fulfilling the local env...

Page 24: ...nal conversion from ToD RS232 signals ToD RS 232 signal on DB9 connector port 6 RJ 45 connector port 4 RS 422 1PPS TTL signal format converter RJ45 connector port 3 TTL high impedance RJ 45 connector...

Page 25: ...etting Started Guide Page 25 of 28 1PPS ToD Frequency Converter Revision D The Calnex external 1pps ToD Frequency converter may be supplied as an option to the Paragon X Opt 133 or ordered separately...

Page 26: ...either sinusoidal or square waveform The frequency output is 1 5V peak to peak square wave into 50 POWER GOOD The POWER GOOD LED is on when power is supplied to the device There is no power switch Po...

Page 27: ...Paragon X Getting Started Guide Page 27 of 28 This page is intentionally blank...

Page 28: ...Paragon X Getting Started Guide Page 28 of 28...

Reviews: