Procedure to install an optical plug-in card
Step
Action
1.
If you have not already done so, remove the optical card from its packaging
and remove the plug cover at the rear of the card.
2.
Pull the card ejector down to the unlocked position.
3.
Slide the card along the guide rails into any universal slot.
Important: To
avoid causing damage to the card or the shelf, align the card correctly
with the guide rails prior to inserting it.
4.
Push the card ejector up into the locked position.
5.
Remove the fiber protector cover from the top front of the card.
6.
Identify the appropriate fiber cable assignments for each optical card (from
the labels applied when you dressed the fiber cables earlier in the installation
process).
7.
Beginning with port 1 at the top of each card, insert the appropriate LC
connector
with the key turned to the right
into the face of the card. (Note:
the Calix optical card ports are located on the face of each card and are
numbered from the top of the card down -1, 2, 3, etc. - with the RX connector
in the front and the TX connector immediately behind it.)
8.
After terminating all the appropriate LC connector ends into the optical card,
replace the card's fiber protector cover.
9.
Repeat steps 1 through 7 for each optical card.
Summary of Contents for ODC-80
Page 1: ...Calix ODC 80 Installation Guide July 2003 Part 220 00029 Rev 11 ...
Page 2: ......
Page 6: ......
Page 7: ...1 Chapter Before You Begin Installing the ODC 80 ...
Page 8: ......
Page 23: ...2 Chapter Placing the ODC 80 on a Pad ...
Page 24: ......
Page 30: ......
Page 31: ...3 Chapter Installing Power Subscriber Cables and Equipment ...
Page 32: ......
Page 74: ......
Page 75: ...4 Chapter Maintaining and Troubleshooting the ODC 80 ...
Page 76: ......
Page 80: ......
Page 92: ......
Page 103: ...5 Chapter Reference ...
Page 104: ......
Page 106: ......