![background image](http://html1.mh-extra.com/html/california-instruments/801p-series/801p-series_user-and-programming-manual_3434434078.webp)
User and Programming Manual - Rev H
California Instruments
May 2000
P Series
70
14.2.3 Output Subsystem
This subsystem controls the main output function of the P Series source.
Subsystem Syntax
OUTPut <bool>
Enable/disable output voltage, current, power, etc.
OUTPut
Command Syntax
OUTPut <bool>
Parameters
0 | 1
*RST Value
OFF
Examples
OUTP 1 OUTP: ON
Query Syntax
OUTPut?
Returned Parameters
0 | 1
Related Commands
*RCL
*SAV
14.2.4 Limit Subsystem
This subsystem controls the voltage frequency and current limit of the power source. These
limits are set at the factory and depend on the power source rating. It is not accessable by the
user. The query format is accessable however.
Subsystem Syntax
LIMit:
FREQuency:
LOW?
Queries the lower frequency limit
HIGH?
Queries the upper frequency limit
VOLTage?
Queries the upper voltage limit
CURRent?
Queries the upper current limit
LIMit:FREQuency:LOW?
This command queries the lower frequency limit of the power source
Command Syntax
LIMit:FREQuency:LOW <NRf>
Parameters
Low freq limit [command protected]
Query Syntax
LIMit:FREQuency:LOW?
Returned Parameters
<NR2>