Troubleshooting
TROUBLESHOOT
• Do not reset breaker multiple times.
• If the unit is overloaded the breaker will trip shutting off the
transformer and lights.
• If the breaker reset button has been held down by hand or any type
of pressure (example: duct tape), or if the breaker has been reset
multiple times without trouble shooting, the unit will:
- Burn the transformer bobbin
- Burn the thermal or magnetic breaker
- Burn the primary or secondary wires due to high amperage caused
by overload and/ or short circuit in line which will not allow the
breaker to reset
- Damage the lighting
1.
Turn off power before beginning. Check for any twisting or damage to
the circuit in the LED lightstrip. If there is excessive damage and
circuit is broken, the lightstrip must be replaced.
2.
Check for metal particles or other foreign objects causing the short.
3.
Check if cut is clean and not frayed, causing positive and negative
copper pads to touch.
4.
Ensure the run is not too long and overlapping.
5.
Ensure copper pads are not making contact with aluminum extrusion.
Frayed end
Metal flakes
Foreign object
Damaged lightstrip
Torn lightstrip
Twisted lightstrip
Lightstrip overlapping extrusion