Calflex CARIMALI 21620-CR Installation Manual Download Page 3

  3 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

Art. 21620-CR 

Art. 21629/A-CR 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

Art. 21720-CR 

Art. 21729/A-CR 

 

 

 

Preparare un foro adeguato nella parete: le quote di installazione sono riportate nella figura (la profondità di incasso 
ammissibile è intesa a parete finita compreso il rivestimento). 
 
Make an appropriate hole in the wall: installation rates are indicated in the picture (allowed built-in depth means at finished 
wall level surface including coating). 
 
Préparer un trou adéquat dans la paroi : 

les dimensions d’installation sont reportées en dessin (la profondeur d’encastrement 

admise s’entend à paroi finie revêtement mural compris). 
 
Bereiten in der Mauer ein passendes Loch vor. Die Anteile der Installation werden im Bild gezeigt. 
Die annehmbare Einbautiefe ist an der beendeten Wand mit Mantel einverstanden. 

 

Summary of Contents for CARIMALI 21620-CR

Page 1: ...NHEBEL ORIZONTAL EINGEBAUTE MISCHBATTERIE F R DUSCHE MIT AUTOMATISCHE MANUELLE UMSTELLUNG Art 21620 CR Art 21629 A CR RUBINETTO MISCELATORE MONOCOMANDO PROGRESSIVO ORIZZONTALE PER DOCCIA INCASSO DEVIA...

Page 2: ...nlet G1 2 upward Cold water inlet G1 2 downward F INFORMATIONS PRELIMINAIRES Les mixers CARIMALI sont adapt s fonctionner avec l eau chaude fournie par accumulateurs en pression Pour le fonctionnement...

Page 3: ...stallation rates are indicated in the picture allowed built in depth means at finished wall level surface including coating Pr parer un trou ad quat dans la paroi les dimensions d installation sont re...

Page 4: ...acilitate cement grip by folding their wings ATTENTION avant l installation et la mise en fonction purger syst me de plomberie v rifier l quilibre des pressions entre l eau chaude et froide v rifier q...

Page 5: ...a level Test the system 16 bar maximum test pressure and test the plumbing system as shown in the following pictures Apr s avoir fait tous les raccords mettre le groupe encastr niveau l aide d un niv...

Page 6: ...dass am Anschluss Nr 1 keine Leckage vorliegt siehe Seite 4 Dann bringen Sie den Knauf wieder in seine Ausgangsposition Auf diese Weise wird der Wasserdurchfluss geschlossen VERSIONE Monocomando Progr...

Page 7: ...ANT La profondeur d encastrement admise est indiqu e aussi sur les protections Beenden Sie bitte den Putz wieder und befestigen Sie bitte den Mantel WICHTIG Die annehmbare Einbautiefe ist auch auf den...

Page 8: ...lize openings to install handles and valves A rev tement fini il faut enlever les plaques de fixation en d vissant les crous avec une cl de 7 mm et les tiges filet es D visser le bouton la tige B pour...

Page 9: ...verify that the connection is at the same level as the finished covering Enlever le bouchon A l aide d une cl de 17 mm Visser le raccord la partie encastrer du robinet avec la cl Allen de 6 mm utilise...

Page 10: ...1 by siliconizing the back of it to make the plate stick and avoid water infiltrations in the wall Make sure not to pinch the O rings Block the plate tightening the nut 2 with a 2 mm Allen wrench Ins...

Page 11: ...te tightening the nut 2 with a 2 mm Allen wrench ATTENTION verify that the rod of the cartridge is turned counterclockwise completely Insert the handle 3 with the hole facing UNDER and block it by tig...

Page 12: ...rench Insert the small plate 5 Insert the spring 6 on diverter rod Screw the button 7 on the rod Ins rer la plaque 1 en mettant de la silicone sur la face arri re pour la coller et viter infiltrations...

Page 13: ...ianto inferiore a un bar si deve premere e ruotare il pulsante in senso orario fino a quando rimane bloccato In questo caso l acqua uscir sempre dalla doccetta Per ritornare in posizione iniziale ruot...

Page 14: ...up the handle The handle regulates the temperature of the mixed water clockwise hot counter clockwise cold Ouvrir l eau et en r gulant le d bit en levant la poign e La poign e r gule la temp rature d...

Page 15: ...water and maximum flow rate Handle fully turned right only hot water and maximum flow rate Fonctionnement du robinet Pour r gler le d bit d eau il faut tourner la poingn e dans le sens horaire Poign...

Page 16: ...2 5 mm e sfilare la manopola 3 Svitare il grano 2 con chiave a brugola da 2 mm Sfilare la piastra 1 Unscrew the button 7 Remove the spring 6 Remove the small plate 5 Unscrew the nut 4 using a 2 5 mm A...

Page 17: ...inem 2 mm Inbusschl ssel l sen Entfernen Sie die Platte 1 Art 21729 A CR Svitare il pulsante 7 Rimuovere la molla 6 Svitare la leva 5 dalla manopola Svitare il grano 4 con chiave a brugola da 2 5 mm e...

Page 18: ...nch Screw the aesthetic ring back on 1 only for 21720 and 21729 A Fermer les entr es d eau chaude et froide D visser la bague esth tique 1 uniquement pour 21620 et 21629 A D visser la bague de fixatio...

Page 19: ...in the correct place Screw the diverter using a 22 mm wrench Fermer la cartouche de m lange D visser le d viateur A avec une cl de 22 mm D filer le d viateur Nettoyer ou remplacer le d viateur R ins r...

Page 20: ...n wrench Insert the small plate 5 Insert the spring 6 on diverter rod Screw the button 7 on the rod Ins rer la plaque 1 en mettant de la silicone sur la face arri re pour la coller et viter infiltrati...

Page 21: ...nut 2 with a 2 mm Allen wrench ATTENTION verify that the rod of the cartridge is turned counterclockwise completely Insert the handle 3 with the hole facing UNDER and block it tightening the nut 4 wi...

Page 22: ...the small plate 5 Insert the small plate 5 Insert the spring 6 on diverter rod Screw the button 7 on the rod Ins rer la plaque 1 en mettant de la silicone sur la face arri re pour la coller et viter...

Page 23: ...s the right to modify the technical features of its articles at any time without notice Pour une politique d am lioration continue CALFLEX S r l se r serve le droit d effectuer des modifications techn...

Page 24: ...24...