High Elevation Installation
Canada.
When installing this appliance at an elevation above 4,500 feet in the
US, it may be necessary to decrease the input rating by changing the
each 1,000 feet above sea level, unless the heating value of the gas
has been reduced, in which case this general rule will not apply. To
When installing this unit at an elevation above 4,500 feet in Canada
check with your local authorities. Consult the local gas utility for assis-
Natural Gas Conversion
CAUTION: This service is to be completed only by an authorized gas
appliance installer. Do not attempt this conversion on your own as
there is risk of serious injury or death.
To The Authorized Gas Appliance Installer:
on liquid propane fuel. Enclosed with this kit is a natural gas conversion
kit for converting this unit to natural gas. To perform this conversion,
follow the directions below and to the local regulation standards in
your area.
1. Make sure unit is not in operation and is cool enough to perform
this service. Shut off and disconnect propane fuel source at the
regulator end.
2.
unit over to access hose connections underneath.
3.
-
move.
4.
same sequence. Turn the protective screen / air intake sleeve to al-
fuel supply tube. Flame should have good retention. For a proper