ITC 220 Base Station, Locomotive & Wayside Radio Transceiver Field Service Guide PN 0046300120 Rev. A
| Page 77
Figure 33 Power cable for Wayside Transceiver externally fused with 10 A ATO.
Figure 34 Wayside Transceiver power connector pin out
D.2 ETHERNET CABLES
BASE STATION AND WAYSIDE TRANSCEIVER ETHERNET CABLES
Base Station and Wayside Transceivers require shielded Category 5 (or better) Ethernet cables with an RJ-45 connector
at each end. It is recommended that the cable length not exceed 100 meters. Receptacles for connecting into the
MAINT and LAN ports of the transceivers are RJ-45 receptacles (jacks).
LOCOMOTIVE TRANSCEIVER ETHERNET CABLE
The Locomotive Transceiver features two 8-pole female M12 A-coded connectors for Ethernet. One is for LAN
communications and the other is for the MAINT port of the transceiver. The LAN Ethernet connection is required for
normal transceiver operation. The MAINT port is for performing maintenance on the unit.
The following figure shows the pin out of the 8-pole female M12-A cable connector used for Ethernet connection.