Figure 2-14 Clone Programmable Parameters Screen
The Clone Programmable Settings writes the currently loaded settings (except the ID Number, Comment,
and Number of Writes) to the EEPROM of the GUARDIAN. This option is used for programming the
same Data
File (.dat) into multiple modems.
2.5.8 DIAGNOSTIC IDS AND ALARMS
The Diagnostics IDs and Alarms screen allows the user to set up the ID List for use with the Offline Link
Test and Offline and Online Diagnostics as well as the Alarms for use with Online Diagnostics.
Figure 2-15 Diagnostic IDs and Alarms Screen
2-20
001-4006-101
ID Entry and List
ID Entry allows the entry of a Long ID to be added to the ID List. The range of this field is 1 to
4294967295 but multiples of 1024 should not be used. A multiple of 1024 results in a Short ID of 0. If the
Long ID is within the range of 1 to 1023, the Short ID will be the same or the resulting Short ID will be
smaller than the Long ID and will be represented by a „+‟ character in front of the ID. A Long ID is added
to the ID List by an „Enter‟ or by pressing the Add ID button.
ID List: Allows the user to select a Long ID from the list to delete. A Long ID is deleted from the list by
pressing the Delete ID button.
Short ID: Shows the converted Short ID from the selected Long ID of the ID List.
Alarms and Filters
Alarms and Filters are used with Online Diagnostics. When Online Diagnostics are received and a
diagnostic field falls outside the Alarm limits, a “<“character will designate a value less than the low
Alarm
and a “>” character will designate a value greater than the High Alarm.