2009 Barbecue Grills and Carts
LTR20091038, Rev. E
Appendix
www.calspas.com
26
Disconnect or shut off the liquid propane or
1.
natural gas line connect to the grill. Wait until
the burners cool down.
Open the hood and remove the grate and flame
2.
tamer on top of the burner you want to replace.
Through the access door underneath the grill,
3.
find the round stud and locking pin that locks the
burner you want to replace.
Carefully remove the locking pin with your
4.
fingers.
Raise the stud from the locking hole and move
5.
the burner forward carefully to release it from
the ignition and gas supply valve.
Take the burner out of the grill and store it in a
6.
safe and dry place.
Install the infrared burner. Align the gas inlet on
7.
the burner with the gas supply valve on the grill
and torch tube with ignition. Make sure they align
perfectly. Slide the stud at the other end into the
locking hole.
Adjust the infrared burner. Make sure the burner
8.
is aligned and in position.
Install the locking pin. Through the access door
9.
underneath the grill, find the stud to lock the
burner in place. Install the locking pin. Make sure
the locking pin is secured correctly.
Repeat steps 2 through 9 if you want to replace
10.
other burners.
Put back the grate you just removed. (You don’t
11.
need the flame tamer for infrared burners.)
Reconnect or turn on the gas line.
12.
If you want to change back to regular burners, just
follow the procedure above in reverse order.
Installing and Replacing Infrared Burners
BTU Ratings
Main burners
15,000 BTU
1.9mm
Infrared burner CF 3 – 5
9,000 BTU
#54 DMS
Infrared burner CF 4
12,000 BTU
#52 DMS
Side burner
13,000 BTU
#50 DMS
Summary of Contents for 2009 Barbecue Grills and Carts