Measurement range:

Function

Range

Accuracy

Sensortype

airtemperature

-10 ~ +50°C

±0,3°C

Thermistor

air humidity

5 ~ 95% of relative air

humidity

±2 %

capacitive sensor

dew point

-30 ~ +100°C

-

Calculates from rel.

humidity and air

temperature the dew

point

Surface temperature as

extra item (STP-10A)

-10 ~ +50°C

±0,5°C

STP 10A external 

3,5 mm jack for

thermocouple connector

 

The illustration shows the most important elements of the equipment: 

To switch on the measuring device, press the function button. When switched on, the device

shows: 

air temperature

relative humidity

dew point

surface temperature 

CAISSON Elektronik GmbH 

Boschstrasse 16, D-47533 Kleve, Deutschland 

tel: +49(0)2821-894390   

[email protected]

   

www.caisson-gmbh.de

Summary of Contents for LVT-15

Page 1: ... device 2 batteries 3 case 4 manual Note The device is supplied with the case Note Surface temperature sensors are not included they are sold separately Art STP 10A Specifications Power supply batteries 2xAA 1 5 volt Current consumption 34mA Dimensions 146mm 79mm 26mm H B T Weight 200 g Display monochromatic with backlight resolution 128x64 pixel Operating conditions 5o C 40o C 80 of rel humidity ...

Page 2: ...rature as extra item STP 10A 10 50 C 0 5 C STP 10A external 3 5 mm jack for thermocouple connector The illustration shows the most important elements of the equipment To switch on the measuring device press the function button When switched on the device shows air temperature relative humidity dew point surface temperature CAISSON Elektronik GmbH Boschstrasse 16 D 47533 Kleve Deutschland tel 49 0 ...

Page 3: ...have other values highlighted Press of the function key six times repeatedly to activate the menu Here the language setting temperature unit automatic switching off and the infobar can be changed The following options can be selected o Language English Deutsch o Temperature units C F 1 Automatic switching off Off 3Min 5Min 10Min determines the lenght of downtime after which switch off automaticall...

Page 4: ...the key for another 2 seconds to deactivate the function In order to get out of the setup menu and back into the measuring mode select SAVE EXIT then keep the key pressed for 2 seconds The following pictures show the described procedure Press the function button Press the functions button 6 times Press and hold the function button for 2 seconds CAISSON Elektronik GmbH Boschstrasse 16 D 47533 Kleve...

Page 5: ...or to activating the device This time can be shortened by gentlye moving the device which will force the air flow across sensor cover The device can also measur the dew point If the temperature of the assistance of a thermal element checked surface is lower or very similar to the dew point temperature then condensation of water on the surface occurs which is signalled acoustically and visually Pow...

Page 6: ...must be provided with a dated proof of purchase Warranty repairs can only be performed by an authorized distributor of CAISSON Warranty does not cover misuse use of force damage caused by external factors or foreign bodies such as sand or water damage caused by failure to comply with the user s instructions normal wear and tear The warranty also excludes devices that are partially or entirely disa...