background image

Stroller

PATIENT OPERATING

INSTRUCTIONS

S

T R O L L E R

®

Sprint

S

P R I N T

Summary of Contents for STROLLER

Page 1: ...Stroller PATIENT OPERATING INSTRUCTIONS S T R O L L E R Sprint S P R I N T...

Page 2: ...ied Part degree of protection against electric shock Warning Information Read this page carefully before using your unit The unit contains liquid oxygen which is extremely cold almost 300 degrees belo...

Page 3: ...2 Patient s Records Patient s Name Prescribed Oxygen Flow Setting Doctor s Telephone Number Distributor s Name Person to Contact Distributor s Emergency Telephone Number Special Instructions...

Page 4: ...r adjust the units yourself Stroller Sprint Table Of Contents Introduction 4 Controls 5 6 Filling Instructions 7 10 Operating Instructions 11 15 Additional Information 16 Specifications Mode of Operat...

Page 5: ...the Stroller Sprint Refer to the POI supplied with the stationary unit for its operation The Liberator is the larger container and is intended for stationary use You may take oxygen directly from the...

Page 6: ...nic Liquid Level Switch 3 Mechanical Liquid Level Gauge 4 Flow Control Knob 5 Oxygen Tube Connector 6 Vent Valve 7 Fill Connections see next page for QDV Identification 8 Carrying Strap with Shoulder...

Page 7: ...Stroller Sprint 6 Portable Connector Stationary Connector QDV Style CAIRE LINCARE CRYO2 LIFE OX PENOX TAEMA PB Side Fill UC SF Locking TF Locking TF Push on Quick Disconnect Valve QDV Identification...

Page 8: ...tion over the stationary unit s connector 4 a If your connector is a push on Lower the Stroller Sprint unit on to the stationary until you feel the connector engage 7 b If your connector is Cryo2 Rota...

Page 9: ...unit to freeze together 2 Make sure the flow control knobs on both the Stroller Sprint and reservoir are in the off 0 position 3 Make the Stroller Sprint fill connector is in the upright position to t...

Page 10: ...he Stroller Sprint is filled 7 You may also see vapor around the connection This is normal and is due to the great difference in temperature between the liquid oxygen and the warm air surrounding the...

Page 11: ...osing the valve at the first sign of liquid discharge does not fill the Stroller Sprint as completely but saves liquid oxygen 9 For the push on style connectors push the release button down until the...

Page 12: ...ob on top of the Stroller Sprint clockwise until the prescribed flow rate numeral is visible in the knob window and a positive detent is felt Warning Out of specification oxygen flow will result if th...

Page 13: ...6 25 5 25 4 05 3 20 2 45 Stroller Sprint 12 5 Use the following chart as a guideline to determine the length of time the Stroller Sprint will operate Note Times are in hours and minutes format 00 00...

Page 14: ...e green operate button on the face of the gauge Read the arc of LEDs which indicates content level Caution The Stroller Sprint is empty if only the last segment of the light bar is lit If the Low Batt...

Page 15: ...exposed colored scale for approximate liquid oxygen contents Note If the unit is empty only the red colored band of the scale will be exposed If this is the case the unit must be filled prior to use 7...

Page 16: ...eplace simply insert pad into bottom cover and rezip the bottom zipper Note If the knob will not push in and engage the cup hold the cup and pull the knob out until it clicks into the open position No...

Page 17: ...rocessing procedure see applicable service manual W WE EE EE E a an nd d R Ro oH HS S This symbol is to remind the equipment owners to return it to a recycling facility at the end of its life per Wast...

Page 18: ...t i v e M e d i c a l P ro d u c t S e r v i c e s B o r n g a s s e 2 0 3 5 6 1 9 B r a u n f e l s G e r m a n y 2 2 0 0 A i r p o r t I n d u s t r i a l D r i v e S t e 5 0 0 B a l l G r o u n d G...

Reviews: