LU00

 

Press 

'OK'

, the display will start flashing.

With touch 

 

and

 

 

adjust the general attenuation UHF level.

Press the 

'OK'

 button again to confirm.

8. Setting B.I/FM, B.III/DAB

B.I + FM, B.III/DAB entries are equipped with attenuators from 0 level to-30dB.

With touch

 

 and 

 

scroll through the filters of your configuration up to

B300

 

Quickly press the 

«OK»

 key.

The display starts to Flash.

Pushing buttons

 

 

and

 

 

can adjust the level of the B.III/DAB filter attenuation.

Press the 

'OK' 

button again to confirm.

Perform the same operation for the adjustment of the B.I/FM after selecting 

 

9 / Power of the entry

Each input can provide a supply voltage of 12 to 24 VDC. 

Procedure:

Programming for TV food menu is accessible only from the "POWER ON" on 
the display of the amplifier status. (screen off, bottom right led). To access the 
State 'POWER ON' simultaneously press keys 

 and 

 

on any screen provided

that it does not blink.

If the amplifier is not yet in the ' POWER ON ' State can force it by 
simultaneously pressing the keys

 

 

and

 

.

Starting from this State, press for 3 seconds on the keys

 

The display shows the menu of remote supply 12 or 24 Volt. 

To continue the procedure and choose the remote supply voltage, press the 

«OK»

 key.

The display will begin to Flash: it is in the mode "programming settings".

Press the buttons

 

 

and

 

 

to select the 12 or 24 Volt voltage.

Push on the 

'OK'

 button again to confirm your choice.

To enable the remote supply or check the presence of voltage at the inputs 

9

B100

Summary of Contents for CAP5510

Page 1: ...CTIONS Digital Terrestrial Programmable Amplifiers CAP5510 REF 0145056R13 CS 60022 46003 Cahors cedex 9 France T l 33 0 5 65 35 82 20 Fax 33 0 5 65 35 82 52 www cahors ced com www groupe cahors com SU...

Page 2: ...Configuration 4 Programming of the filters 5 Deactivation of unused filters 6 UHF input attenuator setting 7 Setting of the cross fader floor 8 B I FM B III DAB and AUX input setting 9 TV supply of t...

Page 3: ...nput can be attenuated by 20 dB if the levels at the terminals of the antennas are too high and each filter has a dynamic of 30 dB programmatically setting in increments of 1 dB The Central also benef...

Page 4: ...e central door c By a tablet with operating system Android 4 0 or successive The application is optimized for tablet with screen from 5 to 10 Correct operation requires that the tablet is equipped wit...

Page 5: ...d and sufficiently ventilated to avoid any risk of overheating do not cover the different ventilation openings It shall be fixed on a flat surface by means of 4 mounting screws 2 Connecting the ANTENN...

Page 6: ...m settings 30 2 the frequency input UHF range programming Press the OK button for 5 seconds the display shows the selection of the frequency range of UHF inputs Ex Press OK the display starts to Flash...

Page 7: ...l enter programming mode This mode lets you set the UHF filters and their gain 10 amplifier filters are freely configurable by width from 1 to 7 channels and attenuation level of 0 to dB Typ 30 Press...

Page 8: ...eys and on any screen provided that it does not blink Press the button for 3 seconds to see the programming of the attenuators menu inputs UHF is displayed The UHF1 input has an attenuation level 0 Br...

Page 9: ...f 12 to 24 VDC Procedure Programming for TV food menu is accessible only from the POWER ON on the display of the amplifier status screen off bottom right led To access the State POWER ON simultaneousl...

Page 10: ...e is finished The linearization algorithm will solve the 115 default dB V output level If you set a 100 dB V output level With an input signal to 70 dB V UHF Interstage attenuator will be set automati...

Page 11: ...soft again 13 PRECAUTIONS FOR USE AND SAFETY This programmable terrestrial plant has been designed in accordance with international safety and security laws in force Please read these instructions for...

Page 12: ...aders to minimum before connecting the antennas If these recommendations are not applied the antenna the Central as well as any other equipment connected to the distribution network could be damaged 8...

Page 13: ...ications of the manufacturer or have the same characteristics as the parts to replace The use of components not following these criteria can damage the plant Attention The following instructions must...

Reviews: