31-2000647 Rev. 2
19
Installation Instructions
ASSEMBLE AND INSTALL
ADAPTOR
B5
Place the microwave oven in its upright position,
with the top of the unit facing up and the front of the
unit facing toward you.
Remove the screw on the back side of the
blower plate and raise the blower plate off of the
microwave.
Slide the damper from left to right into the tabs on
the blower plate. The yellow tape on the damper
should be facing away from you.
Remove the yellow tape from the damper.
Make
sure that the damper pivots easily before
mounting microwave oven.
You will need to make adjustments to assure
proper alignment with your house exhaust duct
after the microwave oven is installed.
Position the blower plate with damper back on the
microwave and secure it with the screws that were
removed.
1
2
3
4
5
5
6
ADAPTING BLOWER FOR
OUTSIDE VENTILATION
B4
.
Slide the blower plate back onto the microwave
by placing the side tabs into the slots and pushing
gently until the back tab is seated into the rear slot,
Replace the blower plate 3 screws.
Slide the blower cover down on the back plate
of the microwave. Replace the blower cover and
blower motor screw.
Side Slot
Side Tab
Rear Tab
Rear Slot
Blower Motor
Screw
Blower
Plate
Damper
Blower Cover
Blower Cover
Screw
Black Plate of Microwave