background image

5.0 INSTALLATION

!

WARNING

RISK

 

OF

 

FIRE

!

 

THE

 

POWER

 

CORD

 

MUST

 

NOT

 

BE

 

PINCHED

 

AGAINST

 

A

 

SHARP

 

EDGE SECURE

 

CORD

 

TO

 

AVOID

 

TRIPPING

 

OR

 

SNAGGING

 

TO

 

REDUCE

 

THE

 

RISK

 

OF

 

FIRE ELECTRIC

 

SHOCK

 

OR

 

PERSONAL

 

INJURY. DO

 

NOT

 

RUN

 

CORD

 

UNDER

 

CARPETING. DO

 

NOT

 

COVER

 

CORD

 

WITH

 

THROW

 

RUGS RUNNERS,

 

ETC

 

ARRANGE

 

CORD

 

.

AWAY

 

FROM

 

CLUTTERED

 

AREAS

 

AND

 

WHERE

 

IT

 

WILL

 

NOT

 

BE

 

TRIPPED

 

OVER. 

RISK

 

OF

 

FIRE

 

TO

 

PREVENT

 

A

 

POSSIBLE

 

FIRE DO

 

NOT

 

BLOCK

 

AIR

 

INTAKE

 

OR

 

EXHAUST

 

IN

 

ANY

 

MANNER DO

 

NOT

 

.

USE

 

ON

 

SOFT

 

SURFACES

 

WHERE

 

OPENINGS

 

MAY

 

BECOME

 

BLOCKED. 

RISK

 

OF

 

FIRE

 

DO

 

NOT

 

BLOW

 

OR

 

PLACE

 

INSULATION

 

AGAINST

 

THE

 

APPLIANCE

.

THIS

 

ELECTRIC

 

APPLIANCE

 

IS

 

TESTED

 

AND

 

LISTED

 

FOR

 

USE

 

ONLY

 

WITH

 

THE

 

APPROVED

 

OPTIONAL

 

ACCESSORIES

 

.

USE

 

OF

 

OPTIONAL

 

ACCESSORIES

 

NOT

 

SPECIFICALLY

 

TESTED

 

FOR

 

THIS

 

ELECTRIC

 

APPLIANCE

 

COULD

 

VOID

 

THE

 

WARRANTY

 

AND/OR

 

RESULT

 

IN

 

A

 

SAFETY

 

HAZARD. 

IF

 

THE

 

INFORMATION

 

IN

 

THESE

 

INSTRUCTIONS

 

IS

 

NOT

 

FOLLOWED

 

EXACTLY A

 

FIRE

 

MAY

 

RESULT

 

CAUSING

 

PROPERTY

 

DAMAGE PERSONAL

 

INJURY

 

OR

 

DEATH DO

 

NOT

 

STORE

 

OR

 

USE

 

GASOLINE

 

OR

 

OTHER

 

FLAMMABLE

 

VAPORS

 

IN

 

THE

 

VICINITY

 

OF

 

THIS

 

OR

 

ANY

 

OTHER

 

APPLIANCE. 

THIS

 

APPLIANCE

 

IS

 

HEAVY IT

 

IS

 

HIGHLY

 

RECOMMENDED

 

THAT

 

TWO

 

PEOPLE

 

INSTALL

 

THIS

 

APPLIANCE.

HEATER

 

VENTS

 

ON

 

THE

 

ELECTRIC

 

APPLIANCE

 

CANNOT IN

 

ANY

 

WAY, BE

 

COVERED

 

AS

 

IT

 

MAY

 

CREATE

 

A

 

FIRE

 

.

.

9

NOTE: Follow all National and local electrical codes.

 

Summary of Contents for CHFP-002

Page 1: ...20 CHFP 50B the similar size as CHFP 30B CHFP 40B CHFP 60B CHFP 74B CHFP 74BS and CHFP 102B SCI 002 the similar size as SCI 001 and SCI 003 HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED N...

Page 2: ...OTING 11 0 WARRANTY WELCOME CONGRATULATIONS MAINTENANCE 3 0 INTRODUCTION 5 1 1 WALL MOUNT INSTALLATION METHOD FOR CHFPV 20 AND SCW SERIES 5 1 2 WALL MOUNT INSTALLATION METHOD FOR CHFP B AND CHFP 74BS...

Page 3: ...0B CHFP 74B CHFP 74BS CHFP 102B SCW 001 SCW 002 SCW 003 1 pc 13 sets 12 sets 18 sets CHFPV 20 CHFP 30B CHFP 40B CHFP 50B SCW 001 CHFP 60B CHFPN 60 CHFP 74B CHFPN 74 CHFP 74BS SCI 001 SCW 002 SCW 003 C...

Page 4: ...sed or qualifed service person Do not strike or slam shut the appliance glass door Keep the packaging material out of reach of children and dispose of the material in a safe manner As with all plastic...

Page 5: ...during installation please contact your local dealer Model Number CHFP 50B Description Wall mount recessed or free standing Appliance Voltage 120V AC Watts Max 1500W Amps 13 AMP Appliance Width 50 127...

Page 6: ...8 861 219mm 56 1 2 20 1 2 5 1 8 1436 521 130mm 70 1 2 20 1 2 5 1 8 1792 521 130mm 98 1 2 20 1 2 5 1 8 2500 522 130mm 26 11 660 280mm 13 1 2 23 1 4 345 592mm 36 14 1 8 915 360mm 46 14 1 8 1168 360mm 60...

Page 7: ...ppliance does not emit heat consult the operation section of this manual for further information D Use with a ETL or UL certified surge protector WARNING READ THESE INSTRUCTIONS COMPLETELY BEFORE BEGI...

Page 8: ...nect appliance turn controls to off then remove plug from outlet Carefully remove the appliance from the box Prior to installing the appliance test to make sure the appliance operates properly by plug...

Page 9: ...INSULATION AGAINST THE APPLIANCE THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE APPROVED OPTIONAL ACCESSORIES USE OF OPTIONAL ACCESSORIES NOT SPECIFICALLY TESTED FOR THIS ELECTRIC...

Page 10: ...have two people lift the appliance up and insert the two hooks on the bracket into the two slots on the back of the appliance D Check the appliance for stability ensuring that the bracket will not br...

Page 11: ...racket will not break free from the wall for screws NOTE CHFP 30B CHFP 40B CHFP 50B CHFP 60B CHFP 74B CHFP 74BS and CHFP 102B Below is the illustration of CHFP 50B for the wall mount bracket and the q...

Page 12: ...P 50B for the quantity of wall anchors that be used for other models please see page3 Installation method for 5 2 2 INSTALLATION METHOD FOR CHFP B AND CHFP 74BS 5 2 1 INSTALLATION METHOD FOR SCW SERIE...

Page 13: ...on the both sides of glass door into the holes in the box Then push down the glass door to its place FRONT VIEW 50 1270mm Screw 8 Stand 2 25 1 4 641mm A 5 3 FREE STANDING INSTALLATION NOTE nly for CH...

Page 14: ...AND SCW SERIES Data Line Power Line A B To disconnect the data line and power line press the plastic connector then pull them out Plastic Connector Plastic Connector C Remove the glass door from appli...

Page 15: ...m tray on the front of the appliance as illustrated Apply an even layer from side to side 15 6 2 1 6 INTERCHANGEABLE MEDIA BED KITS INCLUDED Morocco Dream Winter Flakes Tahiti Getaway Falling Stars Gl...

Page 16: ...holes 6 3 GLASS DOOR INSTALLATION 6 3 1 GLASS DOOR INSTALLATION METHOD FOR CHFPV 20 AND SCW SERIES A To connect power line align the plastic connector and red dot then connect data line B Two people...

Page 17: ...the right of the control panel as illustrated Press this button to turn on the appliance Press again and the button will bounce back The appliance is turned off FRONT VIEW POWER BUTTON 7 1 3 THE BUTTO...

Page 18: ...tion the backlight of this button will be off Under the locked mode HEAT button is not available EN D To change flame color press the COLOR A button There are 3 colors to choose from red yellow and bl...

Page 19: ...to choose from The indicator will show digital 1 to 9 and A to C when changing colors When you press the button for 3 seconds until you hear a beep the indicator will show digital 0 the flame color an...

Page 20: ...60B CHFP 74B CHFP 74BS and CHFP 102B NOTE Control panel is the same as remote control G change flame speed press the SPEED button There are 5 speeds to choose from To The indicator will show V1 to V5...

Page 21: ...B AND CHFP 74BS 7 4 3 CONTROL PANEL THAT IS USED FOR SCI AND CHFPN SERIES NOTE It is used for SCI 001 SCI 002 SCI 003 CHFPN 60 CHFPN 74 and CHFPN 102 21 7 4 1 CONTROL PANEL THAT IS USED FOR CHFPV 20 A...

Page 22: ...k Add to connect WIFI and press Start to configure your device in 60 seconds D When configure succeed it opens e remote device list then click the icon to enter the software If you match several firep...

Page 23: ...ching do not use abrasive cleaners 8 2 CLEANING GLASS DOOR Use only a damp cloth to clean glass door of the fireplace Do not use abrasive cleaners 8 3 SERVICING Except for installation and cleaning de...

Page 24: ...4 5 6 7 8 9 10 11 12 9 0 REPLACEMENT PARTS 1 800 306 3829 STAND Take the replacement parts of CHFP 50B for example NOTE Care must be taken when removing and disposing of any broken glass or damaged c...

Page 25: ...crews on the mirror glass CHP 007 Replace the LED circuit board CHP 001 There is something wrong with the circuit board Replace the circuit board CHP 002 Replace the transformer CHP 008 No warm air co...

Page 26: ...es related to the reinstallation of a warranted part and such expenses are not covered by this warranty Notwithstanding any provisions contained in the Limited Warranty CAESAR FIREPLACE s responsibili...

Reviews: