background image

Operating

and

Installation Instructions

CHARNWOOD

COUNTRY 4

Bishops Way, Newport, Isle Of Wight, PO3O 5WS, U.K.

Tel: (01983) 527552

Fax: (01983) 821267

Internet: www.charnwood.com Email: [email protected]

Summary of Contents for FIREPIT

Page 1: ...Operating and Installation Instructions CHARNWOOD COUNTRY 4 Bishops Way Newport Isle Of Wight PO3O 5WS U K Tel 01983 527552 Fax 01983 821267 Internet www charnwood com Email charnwood ajwells co uk ...

Page 2: ...e At first you may find it helpful to try several fuels to find the most suitable If you are unable to obtain the fuel you want ask your supplier or an approved fuel distributor to suggest an alternative Only smokeless fuels may be burnt in smoke control areas FITTING THE OPTIONAL COAL KIT Before burning coal or smokeless fuel the coal kit must be fitted This consists of a grate a coal retainer an...

Page 3: ...hen burning coal or smokeless fuel there is a special Charnwood ash carrier available This enables the whole ashpan to be placed in the sealed carrier and taken outside These may be purchased from your supplier or in case of difficulty directly from ourselves SPECIAL POINTS WHEN BURNING HOUSE COAL When loading the stove take care not to smother the fire instead fill the firebox in two stages waiti...

Page 4: ... replace the throat plate see Fig 2 and the fuel retainer Different types of sweep s brushes are available to suit different flueways For standard brick chimneys a wire centre sweep s brush fitted with a guide wheel is recommended For prefabricated insulated chimneys the manufacturers instructions with regard to sweeping should be consulted TROUBLE SHOOTING Fire Will Not Burn Check that a the air ...

Page 5: ...ety these must be kept clean Fire blazing out of control Check that a The door is tightly closed b The spin wheel is fully closed c The airwash control is closed d A suitable fuel is being used e Door seals and airwash slide are intact Chimney Fires If the chimney is thoroughly and regularly swept chimney fires should not occur However if a chimney fire does occur close the spin wheel and the airw...

Page 6: ... which the appliance is installed totalling at least 100 square cm 16 square inches to provide combustion air In addition to these instructions the requirements of BS 8303 and BS 6461 Pt 1 2 1984 must be fulfilled Local Authority Bylaws and Building Regulations regarding the installation of Solid Fuel burning appliances flues and chimneys must also be observed PERFORMANCE The output of the Country...

Page 7: ...sh through the appliance but in most back outlet installations it will be necessary to have a soot door to enable the chimney to be swept The optional vertical rear flue connector does allow the chimney to be swept through the stove Soot doors may either be in the actual brickwork of the chimney or in the register plate Various positions of soot doors are shown in Figs 3 to 6 PRE LIGHTING CHECK En...

Page 8: ...Overall Dimensions All dimensions are in mm Page 8 Country 4 7 98 b ...

Reviews: