Polarity Inverters
–
User’s Ma
nual
10
These polarity inverters have the following ratings listed in
Model
Description
Maximum Voltage
Maximum Current
WPOLINV200XA
200 A Polarity Inverter
250 V
200 A
WPOLINV400XA
420 A Polarity Inverter
250 V
420 A
WPOLINV600XA
630 A Polarity Inverter
250 V
630 A
Table 1:
Main ratings of the polarity inverters.
If the rear power connections of the Polarity Inverter are
accessible, IN and OUT connections result in HAZARDOUS
LIVE parts and must be isolated or confined following local
regulations.
If the Maximum Voltage level is below 70 V
DC
further
isolations are not required.
All these polarity inverters are already supplied with the signal cable that allows
connecting them directly to an NGPS power supply.
WARNING