Capital Automotive Equipment
Model:4PG8000
1
Every six months check the nuts of all anchor bolts for correct installation torque Tinst.
2
Retighten them as required.
Installation Torque Tinst
4PG8000
80 Nm
7.4 Cleaning
Do not use high pressure / steam jet cleaners or caustic cleaning agents.
Risk of damage!
1
Periodically wash off aggressive substances and treat the lift with oil or wax spray.
2
Repair damage to the paintwork immediately to prevent corrosion. The RAL number is
available through the manufacturer.
Chapter 8 Trouble shooting
A list of possible troubles and solutions is given below:
TROUBLE
:
POSSIBLE CAUSE
:
SOLUTION
:
The lift does not work
The main switch is not turned on
Turn the switch on
There is no power
Check Power on to restore if
necessary
The electrical wires are disconnected
Reconnect
Fuses are blown
Check for correct voltage
Replace
The lift does not raise
The lift is overloaded
Check the vehicle weight
The motor direction of rotation is not
correct.
Interchange the two phases on
the main switch
The oil in the power unit is not sufficient.
Add some hydraulic oil
The UP button is faulty.
Check
UP
button
and
connection for proper operation.
Replace if needed
The maximum pressure valve clogged or
leaks
Check and clean if dirty
or
replace if faulty
The lowering valve does not close.
Check and clean, if dirty or
replace if faulty