31
Setup
Attaching the Overflow Bottle to the Trauma Fill Tank Assembly
The overflow bottle is used to collect overflow when the METIman on-board tank is filled.
To attach the Overflow Bottle to the Trauma Fill Tank:
Connect the clear trauma fill tank hose to the bottle lid fitting.
1.
Connecting the Trauma Fill Tank Umbilical to the Overflow Bottle
Clip the bottle to the tank using the attached carabiner mechanism.
2.
The Carabiner
Operating the Trauma Fill Tank
Be careful to complete the following steps correctly to ensure proper use and maintenance of
the METIman and its peripherals.
Step 1: Pour the Fluid into the Trauma Fill Tank
Pour the desired amount of fluid into the Trauma Fill Tank, being careful to NOT to exceed 6
liters (1.6 gallons) of fluid.
NOTE
: The right thigh tank holds 1.5 liters and is used for blood.
Three (3) liters of simulated blood provides enough fluid to fill the right thigh reservoir twice.
The amount of blood used in a training session varies with the patient, the wounds simulated
and the learner’s experience.
Connect the
clear hose to the
bottle lid fitting
The carabiner