background image

6” Min.

6” Min.

6” Min.

6” Min.

Figure 7

Figure 6

Installation Instructions

The C Series REQUIRES A MINIMUM distance of
6 inches from all adjacent surfaces. However, Cadet
RECOMMENDS 12 inches from all adjacent surfaces
for longer and cleaner performance.

Important:

Do not mount the heater in low-density fiberboard
or false ceilings.

Secure the wall can to studs/rafters on opposite sides
(See Figures 6 and 7) with 4 screws (not provided).
The face of the wall can must extend

1

/

2

or

5

/

8

inches

from face of rafters to allow for thickness of sheetrock.

Insulating materials may touch the wall can however,
“blown-in” insulation is not recommended as it could
be drawn into the heater through gaps behind the grill.
For ceiling installation, the wall can must be boxed in
with wood on all sides and back to prevent dust from
entering the heater through the ceiling cavity.

Part One

WARNING

Risk of Electrical
Shock. Connect
grounding lead
to grounding wire
provided. Keep
all foreign objects
out of heater.

WARNING

Risk of Fire.
Heater must be
kept clear of
all obstructions:
a minimum
of 3 feet in front;
6 inches on both
sides and above.
Heaters must be
kept clean of lint,
dirt and debris.

WARNING

Turn the electrical
power off at the
electrical panel
board (circuit
breaker or fuse
box) and lock or
tag the panel board
door to prevent
someone from
turning on power
while you are
working on the
heater. Failure to
do so could result
in serious electrical
shock, burns, or
possible death.

STEP 1

Mount the Wall Can

Route supply wire from circuit breaker to thermostat
to wall can.

Models with a built-in thermostat are not

recommended for ceiling mount.

Remove a knockout

in the wall can and attach the supply wire with a strain
relief connector leaving 10 inches wire lead for later
use (See Figure 3). Connect supply ground wire to
grounding pigtail in wall can. Proceed to Part Two.

STEP 2

Route Supply Wires

Figure 9

Figure 8

How do I insert the heater assembly
into the wall can?

Turn heater assembly upside-down (element down)
with motor facing you. Connect the supply wires to
the heater wires with wire connectors (See Figure
8). Now rotate the heater so the element and fan are
facing you (with the element ‘up’). Insert the bottom
edge of the heater assembly into the tabs in the
bottom lip of the wall can (See Figure 9).

Important

: Push wires into bottom of wall can during

insertion. Be sure that supply wires are not caught
between motor and wall can. Attach assembly at top
with screw provided.

Part Two

After you have followed all instructions in PART ONE

you are ready to install the heater assembly.

TOP

MOTOR

WIRE 
CONNECTOR

GROUNDING
PIGTAIL

WIRE

CONNECTOR

HEATER WIRES

SUPPLY

WIRES

BACK

Secure grill with the screws provided. If you have a
built-in thermostat model, slide thermostat knob onto
shaft. Turn power on at the electrical panel board.

Warranty is void if any material is sprayed on the
element or blower.

STEP 1

Install Heater Assembly

STEP 2

Install Grill

How do I install for ceiling mount?
(for models up to 1500 Watts maximum)

3

All manuals and user guides at all-guides.com

Summary of Contents for The Com-Pak Plus C051 reset

Page 1: ...as hot and arcing or sparking parts inside Do not install heater in any area where combustible vapors gases liquids or excessive lint or dust are present 9 WARNING Burn Hazard This heater is hot when in use To avoid burns do not let bare skin touch hot surfaces Use extreme caution when any heater is used by or near children or invalids and whenever the heater is left operating unattended 10 WARNIN...

Page 2: ... output Hooking a 120 volt heater to a 240 volt power supply will destroy the heater Connecting your heater to an incompatible power supply will void the warranty Part One PLACEMENT Install The Com Pak Plus Model C vertically recommended or horizontally Model C may be installed in the ceiling for models up to 1500W maximum See ceiling mount instructions The Com Pak Twin Plus Model CT must be insta...

Page 3: ...ical shock burns or possible death STEP 1 Mount the Wall Can Route supply wire from circuit breaker to thermostat to wall can Models with a built in thermostat are not recommended for ceiling mount Remove a knockout in the wall can and attach the supply wire with a strain relief connector leaving 10 inches wire lead for later use See Figure 3 Connect supply ground wire to grounding pigtail in wall...

Page 4: ...e with screws 9 Turn thermostat to desired setting 10 Turn power back on at the electrical panel board About the Heater Temperature Limiting Controls The heater is protected by two temperature limiting controls for Model CT four controls are used The first is a high temperature manual reset limit control designed to open the heater circuit when excessive operating temperatures are detected The pro...

Page 5: ...res repair or replacement 1 Adjust thermostat to a higher temperature until heater operates see Problem 6 if the problem persists 2 Press the manual reset button see Operation Maintenance section for instructions 3 A severe over temperature condition has occurred Repair or replace heater 4 Turn on the correct circuit breaker in the main panel 5 Turn off power at circuit breaker Check supply wire c...

Page 6: ...mación Verifique que todos los cables de suministro eléctrico sean del mismo voltaje que el calentador 3 Todo trabajo y materiales eléctricos deben cumplir con el Código Eléctrico Nacional NEC por su sigla en inglés con la Ley de Seguridad y Salud Ocupacional OSHA por su sigla en inglés y con todos los códigos estatales y locales 4 Conecte el alambre de tierra en espiral de cobre que viene en la c...

Page 7: ... circuito al termostato al calentador Para los modelos con termostato incorporado colocar el cable de suministro desde el interruptor de circuito al calentador Quitar una de las piezas desmontables y colocar el cable de suministro con un conector de alivio de tensión dejando el conector de cable de 10 para poder utilizarlo más tarde Ver la Figura 3 Conectar el cable de suministro a tierra con el c...

Page 8: ...All manuals and user guides at all guides com ...

Page 9: ...All manuals and user guides at all guides com ...

Page 10: ... 2007 Cadet Manufacturing Co Printed in U S A Rev 11 07 720080 All manuals and user guides at all guides com ...

Reviews: