Installation Instructions

How do I install for
new construction walls?

Figure 1

Face of wall can must
extend

1

/

2

inch or

5

/

8

inch

from face of stud to allow
for thickness of sheetrock.

STEP 1

Mount The Wall Can

How do I install in an existing wall?

STEP 1

Cut Hole In Wall

Route supply wire from circuit breaker to thermostat
to wall can. For models with built-in thermostat, route
supply wire from circuit breaker to wall can. Remove
a knockout and attach the supply wire with a strain
relief connector leaving 10 inches wire lead for later
use. Connect supply ground wire to grounding pigtail
in wall can (See Figure 3). Proceed to PART TWO.

STEP 2

Route Supply Wires

Route supply wire from circuit breaker to thermostat
to wall can. For models with built-in thermostat, route
supply wire from circuit breaker to wall can. Remove
a knockout and attach the supply wire with a strain
relief connector leaving 10 inches wire lead for later
use (See Figure 3). Connect supply ground wire to
grounding pigtail in wall can.

STEP 2

Route Supply Wires

Review the wall can label for correct direction
(as noted by the UP arrows) before mounting the
wall can in the opening. In the VERTICAL mounting
position the elements of the heater assembly will be
at the top, in the HORIZONTAL mounting position the
elements of the heater assembly will be to the left.

Insert wall can into opening. Keeping wall can flush
with wall, secure Model C to wall stud with 2 screws
and Model CT to both wall studs with 4 screws.
Proceed to PART TWO.

Mount Wall Can

Figure 2

Attach wall can to
stud with screws.
(Model C shown)

Figure 3

Figure 4
Model C

14

5

/

8

READ ALL

INSTRUCTIONS

AND SAFETY

INFORMATION

IMPORTANT!

It is extremely

important you verify

that the electrical

supply wires are

the same voltage as

the heater (i.e. 120

volt heater to 120

volt power supply

and 240 volt heater

to 240 volt power

supply). If replacing

an existing heater,

check the labels of

the old heater and

replace using the

same voltage.

Hooking a 240 volt

heater to a 120 volt

power supply will

drastically reduce

the heater’s output.

Hooking a 120 volt

heater to a 240 volt

power supply will

destroy the heater.

Connecting your

heater to an

incompatible

power supply will

void the warranty.

Part One

PLACEMENT:

Install The Com-Pak Plus (Model C) vertically (recommended) or horizontally. Model C may be

installed in the ceiling (for models up to 1500W maximum. See ceiling mount instructions.) The Com-Pak Twin Plus
(Model CT) must be installed with the arrows in the wall can pointing upwards.

THERMOSTAT:

A thermostat is required for models without a built-in thermostat.

A Cadet Electronic Thermostat or

Cadet Dual Diaphragm Thermostat is recommended for ultimate control and comfort.

Figure 5
Model CT

STEP 3

The C Series REQUIRES A MINIMUM distance of
6 inches from adjacent surfaces and 4

1

/

2

inches from

the floor (See Figure 4) and the CT Series REQUIRES
A MINIMUM distance of 6 inches from adjacent
surfaces and 4

1

/

2

inches from the floor (See Figure 5).

However, Cadet RECOMMENDS 12 inches from all
adjacent surfaces and 12 inches above the floor for
longer and cleaner performance. Heaters must be
spaced at least 3 feet apart.

Review the wall can label for correct direction
(as noted by the UP arrows) before mounting the
wall can in the opening. In the VERTICAL mounting
position the elements of the heater assembly will be
at the top, in the HORIZONTAL mounting position the
elements of the heater assembly will be to the left.

Model C:

Secure the wall can to the stud with

2 screws (See Figures 1 & 2). As an option, the rubber
shim provided may be attached to side of wall can to
square the wall can to the stud.

Model CT:

Secure the wall can to studs on both sides

with 4 screws.

Model C:

Cut a hole 8 inches wide by 10

1

/

4

inches

high next to wall stud. The C Series REQUIRES
A MINIMUM distance of 6 inches from adjacent
surfaces and 4

1

/

2

inches from the floor. However,

Cadet RECOMMENDS 12 inches from all adjacent
surfaces and 12 inches from the floor (See Figure 4).

Model CT:

Cut a hole 14

5

/

8

inches wide by 10 inches

high next to wall stud. The CT Series REQUIRES
A MINIMUM distance of 6 inches from adjacent
surfaces and 4

1

/

2

inches from the floor. However,

Cadet RECOMMENDS 12 inches from all adjacent
surfaces and 12 inches from the floor (See Figure 5).

2

All manuals and user guides at all-guides.com

Summary of Contents for The Com-Pak Plus C051 reset

Page 1: ...as hot and arcing or sparking parts inside Do not install heater in any area where combustible vapors gases liquids or excessive lint or dust are present 9 WARNING Burn Hazard This heater is hot when in use To avoid burns do not let bare skin touch hot surfaces Use extreme caution when any heater is used by or near children or invalids and whenever the heater is left operating unattended 10 WARNIN...

Page 2: ... output Hooking a 120 volt heater to a 240 volt power supply will destroy the heater Connecting your heater to an incompatible power supply will void the warranty Part One PLACEMENT Install The Com Pak Plus Model C vertically recommended or horizontally Model C may be installed in the ceiling for models up to 1500W maximum See ceiling mount instructions The Com Pak Twin Plus Model CT must be insta...

Page 3: ...ical shock burns or possible death STEP 1 Mount the Wall Can Route supply wire from circuit breaker to thermostat to wall can Models with a built in thermostat are not recommended for ceiling mount Remove a knockout in the wall can and attach the supply wire with a strain relief connector leaving 10 inches wire lead for later use See Figure 3 Connect supply ground wire to grounding pigtail in wall...

Page 4: ...e with screws 9 Turn thermostat to desired setting 10 Turn power back on at the electrical panel board About the Heater Temperature Limiting Controls The heater is protected by two temperature limiting controls for Model CT four controls are used The first is a high temperature manual reset limit control designed to open the heater circuit when excessive operating temperatures are detected The pro...

Page 5: ...res repair or replacement 1 Adjust thermostat to a higher temperature until heater operates see Problem 6 if the problem persists 2 Press the manual reset button see Operation Maintenance section for instructions 3 A severe over temperature condition has occurred Repair or replace heater 4 Turn on the correct circuit breaker in the main panel 5 Turn off power at circuit breaker Check supply wire c...

Page 6: ...mación Verifique que todos los cables de suministro eléctrico sean del mismo voltaje que el calentador 3 Todo trabajo y materiales eléctricos deben cumplir con el Código Eléctrico Nacional NEC por su sigla en inglés con la Ley de Seguridad y Salud Ocupacional OSHA por su sigla en inglés y con todos los códigos estatales y locales 4 Conecte el alambre de tierra en espiral de cobre que viene en la c...

Page 7: ... circuito al termostato al calentador Para los modelos con termostato incorporado colocar el cable de suministro desde el interruptor de circuito al calentador Quitar una de las piezas desmontables y colocar el cable de suministro con un conector de alivio de tensión dejando el conector de cable de 10 para poder utilizarlo más tarde Ver la Figura 3 Conectar el cable de suministro a tierra con el c...

Page 8: ...All manuals and user guides at all guides com ...

Page 9: ...All manuals and user guides at all guides com ...

Page 10: ... 2007 Cadet Manufacturing Co Printed in U S A Rev 11 07 720080 All manuals and user guides at all guides com ...

Reviews: