Page 1: ...as hot and arcing or sparking parts inside Do not install heater in any area where combustible vapors gases liquids or excessive lint or dust are present 9 WARNING Burn Hazard This heater is hot when in use To avoid burns do not let bare skin touch hot surfaces Use extreme caution when any heater is used by or near children or invalids and whenever the heater is left operating unattended 10 WARNIN...

Page 2: ... output Hooking a 120 volt heater to a 240 volt power supply will destroy the heater Connecting your heater to an incompatible power supply will void the warranty Part One PLACEMENT Install The Com Pak Plus Model C vertically recommended or horizontally Model C may be installed in the ceiling for models up to 1500W maximum See ceiling mount instructions The Com Pak Twin Plus Model CT must be insta...

Page 3: ...ical shock burns or possible death STEP 1 Mount the Wall Can Route supply wire from circuit breaker to thermostat to wall can Models with a built in thermostat are not recommended for ceiling mount Remove a knockout in the wall can and attach the supply wire with a strain relief connector leaving 10 inches wire lead for later use See Figure 3 Connect supply ground wire to grounding pigtail in wall...

Page 4: ...e with screws 9 Turn thermostat to desired setting 10 Turn power back on at the electrical panel board About the Heater Temperature Limiting Controls The heater is protected by two temperature limiting controls for Model CT four controls are used The first is a high temperature manual reset limit control designed to open the heater circuit when excessive operating temperatures are detected The pro...

Page 5: ...res repair or replacement 1 Adjust thermostat to a higher temperature until heater operates see Problem 6 if the problem persists 2 Press the manual reset button see Operation Maintenance section for instructions 3 A severe over temperature condition has occurred Repair or replace heater 4 Turn on the correct circuit breaker in the main panel 5 Turn off power at circuit breaker Check supply wire c...

Page 6: ...mación Verifique que todos los cables de suministro eléctrico sean del mismo voltaje que el calentador 3 Todo trabajo y materiales eléctricos deben cumplir con el Código Eléctrico Nacional NEC por su sigla en inglés con la Ley de Seguridad y Salud Ocupacional OSHA por su sigla en inglés y con todos los códigos estatales y locales 4 Conecte el alambre de tierra en espiral de cobre que viene en la c...

Page 7: ... circuito al termostato al calentador Para los modelos con termostato incorporado colocar el cable de suministro desde el interruptor de circuito al calentador Quitar una de las piezas desmontables y colocar el cable de suministro con un conector de alivio de tensión dejando el conector de cable de 10 para poder utilizarlo más tarde Ver la Figura 3 Conectar el cable de suministro a tierra con el c...

Page 8: ...All manuals and user guides at all guides com ...

Page 9: ...All manuals and user guides at all guides com ...

Page 10: ... 2007 Cadet Manufacturing Co Printed in U S A Rev 11 07 720080 All manuals and user guides at all guides com ...