INSTALLATION INSTRUCTIONS
WARRANTY
For more effective and safer operation and to
prolong the life of the heater, read the Owner’s
Guide and follow the instructions. Failure to properly
maintain the heater will void any warranty and may
cause the heater to function improperly.
LIMITED FIVE YEAR WARRANTY:
Cadet will re-
pair or replace any Energy Plus (CE) heater found
to be defective within five years after the date of
purchase.
These warranties do not apply:
1. Damage occurs to the product through improper
installation or incorrect supply voltage;
2. Damage occurs to the product through improper
maintenance, misuse, abuse, accident, or alteration;
3. The use of unauthorized accessories or unau-
thorized components constitutes an alteration and
voids all warranties. Refer to Cadet website or call
customer service at 855.223.3887 or 360.693.2505
for list of authorized accessories and components.
4. Cadet’s warranty is limited to repair or replace-
ment.
5. In the event Cadet elects to replace any part of
your Cadet product, the replacement parts are sub-
ject to the same warranties as the product. The in-
stallation of replacement parts does not modify or
extend the underlying warranties. Replacement or
repair of any Cadet product or part does not create
any new warranties.
If you believe your Cadet product is defective,
please contact Cadet during the warranty period,
for instructions on how to have the repair or
replacement processed.
Parts and Service
Visit
cadetheat.com/parts-service
for information on
where to obtain parts and service.
To register your product, visit
cadetheat.com/product-registration
BLUE
RED
YELLOW
BLACK
MOTOR
HEATING ELEMENT
HIGH-TEMPERATURE
SAFETY SHUTOFF
DIGITAL
THERMOSTAT
BLACK
BLACK/
WHITE
L1
L2
WHITE RED BLACK
INTERNAL HEATER WIRING DIAGRAMS
Figure 5
this set of wires from
the circuit breaker
additional
copper wire
connected here
to grounding
screw
MULTIPLE HEATERS ON ONE CIRCUIT BREAKER (240 or 208 volts only)
1. Route the electrical supply wire from the circuit breaker to heater #1. Remove two knockouts and
attach two sets of electrical supply wire with two cable clamp connectors (not included) leaving a mini-
mum of 6 inches wire lead—one set from the circuit breaker, the other set to heater #2 (See Figure 5).
2. The two supply ground wires in the wall can of heater #1 need to make a 3-wire connection with the
grounding screw. Attach a short copper ground wire to the grounding screw in the wall can. Connect
this wire and the two supply ground wires with a wire connector (not included). (See Figure 5).
3. For heater #1, connect each heater wire with one of the supply wires going to the circuit breaker, and
one of the supply wires going to heater #2. Each of the wires from heater #1 must have a 3-wire con-
nection. For heater #2, make the connections in the wall can as shown below.
More than one heater can be wired in parallel on the same circuit breaker (be sure to check national and
local codes for safety requirements). Additional electrical supply wire and cable clamp connectors are
required. The heaters must be in the same room.
Maximum amperage you can put on one circuit breaker is limited to 80% of the circuit breaker capacity.
this set of wires
from heater #1
heater #1
(back)
heater #2
(back)
this set of wires
to heater #2
After making all connections, go to Page 5 and proceed with STEP 4
Finish installation
, number 4.
6
RED
YELLOW
BLACK
MOTOR
HEATING ELEMENT
HIGH-TEMPERATURE
SAFETY SHUTOFF
DIGITAL
THERMOSTAT
BLACK
BLACK/
WHITE
L1
L2
WHITE RED BLACK
RED
YELLOW
BLACK
MOTOR
HEATING ELEMENT
HIGH-TEMPERATURE
SAFETY SHUTOFF
DIGITAL
THERMOSTAT
BLACK
BLACK/
WHITE
L1
L2
ORANGE
RED BLACK
CE168T 208 Volt
CE162T 240 Volt
CE163T/CE083T Multi-Volt