PROBLEM
CAUSE
SOLUTION
INTERVENTION
Flames are weak and
orange coloured,
pellets do not burn
properly and the
glass blackens
Not sufficient com-
bustion air
Check as following: probable obstructions of the combustible air
inlet from the back or from the bottom of the stove; burning pot
obstructed holes with too ash remains. Have the fan blades and au-
ger cleaned.
Obstructed exhaust
The exhaust chimney is partially or totally obsturcted. Contact an
expert stove-repairer who checks the stove from the exhaust up to
the chimney pot. Provide immediately for stove cleaning.
Obstructed stove
Provide immediately at the inner cleaning of the stove.
The fume fan is out
of order
The pellets can burn also thanks to chimney flue depression without
the aid of the fume fan. Have the fume fan immediately replaced. It
can be noxious to health to let the stove running without fume fan.
The exchanger fan
continues to turn
even though the
stove has just cooled
Faulty fume tempe-
rature probe
Replace the fume probe.
Faulty mother board Replace the mother board.
Ash remains along
the stove
Faulty or out of order
door gaskets
Replace the gaskets.
Not sealed fume
pipes
Contact an expert stove-repairer who will immediately provide for
sealing the junctions with high-temperature silicone and/or for re-
placing pipes with those in compliance to current regulations. A not
sealed fume channelisation can be noxious to health.
The stove is at its
highest power but
does not heat up.
Ambient temperatu-
re reached.
The stove is at its minimum value. Increase the desired ambient
temperature.
Stove running and
display showing
"Smoke Overtepe-
rature"
Reached fume outlet
limit temperature
The stove runs at minimum. NO PROBLEM!
The stove's smoke
duct produces
condensation
Low smoke tempe-
rature
Check that the flue is not clogged.
Increase stove power to minimum (pellet drop and fan revs).
Install condensation collection cup.
Stove running and
display showing
"SERVICE"
Routine maintenan-
ce alert (it does not
block the system)
When this flashing message appears upon start-up, it means that
the preset operating hours have elapsed before maintenance. Con-
tact the service centre.
“Pellet reserve
enabling” activates
with the tank full
Failure to reach the
threshold tempera-
ture, large or poor
quality pellet, clog-
ged fume passage
Increase pellet with “Pellet Recipe” or clean the combustion cham-
ber