6.21 STOVE CALIBRATION AND DEPRESSION MEASUREMENT
This stove has a pickup point positioned on the tank in order to measure the depression of the combustion chamber and verify its
proper operation.
To do this, proceed as follows:
• Connect a digital pressure switch with a tube to detect the negative pressure (see
).
• Load the feed screw via appropriate function.
• Start the stove and set "Set flame" to power 1 (the start-up time of this stove lasts between 8 and 10 minutes to ensure mini-
mum draught).
• Compare the read values with those on the table.
• Change power every 10 minutes and wait for it to stabilise.
• Access the user menu and, if necessary, change the parameters.
Fig. 61 - Casing removal
Fig. 62 - Digital pressure switch connection
Fig. 63 - Digital pressure switch connection
DATA
P1
P2
P3
P4
P5
Stove depression -
temperature 5 kW
25/26 Pa - 190°C
29/30 Pa - 185°C
31/32 Pa - 195°C
35/36 Pa - 210°C
38/39 Pa - 220°
Stove depression -
temperature 7 kW
25/26 Pa - 190°C
29/30 Pa - 200°C
34/35 Pa - 220°C
40/41 Pa - 240°C
47/48 Pa - 250°
NB: for good combustion, the depression values must be b -5 Pa and the temperature values b - 10°C.
7
SPECIAL MAINTENANCE
7.1
INTRODUCTION
For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
• Fume outlet pipes (fume c chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an autho-
rized technician in compliance with local regulations, with the instructions of the manufacturer and those of your insurance
company.
• If there are no local regulations and no instruction from your insurance company, it is necessary to have your fume pipe, chim-
ney flue and chimney pot cleaned at least once a year.
• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and the electronical
elements checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance Service.
• After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
• If the stove had been using continuously and intensely, the whole system (chimney included), must be cleaned and checked
more frequently.