background image

SHELL UP - SHELL PS -BREEZE AIRTIGHT

4

According to (EU) No. 305/2011 regulation, the " Declaration of Performance" and "Declaration of Conformity" are available online, 

in the download area, at the web sites: 

- www.cadelsrl.com

- www.free-point.it

- www.pegasoheating.com

Having specified the above, we highlight and report that:

• 

This manual and technical data sheet, also available on our website

, bear all of the specific indications and necessary 

and essential information to choose the product, to install it correctly and to properly size the smoke expulsion system; 

•  the Products must be

 installed, controlled and serviced 

by a qualified operator, according to the instructions in this ma-

nual and in compliance with the laws and installation and maintenance standards in force in individual countries, so as to 

provide an efficient heating system, properly sized according to the needs of the home.

• 

If the Products are thermally stressed

, constantly operating for several hours at high power (e.g. 3, 4 hours a day at ou-

tputs P4 or P5), we recommend more frequent cleaning and reducing the interval between routine maintenance operations 

according to the operating condition of the product. We furthermore point out that these operating conditions increase the 

risk of premature wear of the product, especially those parts exposed to the direct heat of the fire (e.g. combustion chamber), 

the original condition of which can undergo modifications and deterioration which, among other things, could generate noise 

during operation of the unit due to mechanical expansion.

The manufacturer will not be held liable if the above information is ignored.

2.1 

REVISIONS TO THE PUBLICATION

The content of this manual is strictly technical and the property of CADEL S.r.l.

No part of this manual may be translated into other languages, adapted and/or reproduced, even in part, in other mechanical and/

or electronic form or media, for photocopies, recordings or other, without the prior written authorisation of CADEL S.r.l.

The company reserves the right to make changes to the product at any time without prior notice. The owner company reserves its 

rights according to law.

2.2 

CARE OF THE MANUAL AND HOW TO CONSULT IT

•  Take care of this manual and store it in an easily and quickly accessible place.

•  Should this manual be lost or destroyed, request a copy from your retailer or directly from the authorised Technical assistance 

department. It can also be downloaded from the company’s website.

• 

“Bold text”

 requires special attention.

Summary of Contents for SHELL3 UP

Page 1: ...EN USER MANUAL Pellet Stove 2022CADELsrl Allrightsreserved Tuttiidirittiriservati new SHELL3 UP SHELL3 PS BREEZE AIRTIGHT...

Page 2: ...U 19 8 16 EASYSETFEATURE SEESECTIONXSETTINGSMENU A PAG 13 20 8 17 PELLETS RECIPE SEE SECTION H SETTINGS MENU A PAG 13 21 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 21 8 19 CHIMNEY S...

Page 3: ...nload it directly from the company s website Alllocalregulations includingthosereferringtonationalandEuropeanstandards mustbeobservedwheninstallingtheappliance In Italy for the installation of systems...

Page 4: ...operating condition of the product We furthermore point out that these operating conditions increase the risk of premature wear of the product especially those parts exposed to the direct heat of the...

Page 5: ...meter If the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleani...

Page 6: ...theproductisswitchedonforthefirsttime itisnormalforittoemitsmokeduetothepaintheatingupforthefirsttime Therefore make sure the room it is installed in is well ventilated Periodically check and empty th...

Page 7: ...ault the customer must have the guarantee certificate and present it with the proof of purchase document to theTechnical Assistance Office Theguaranteedoesnotcovermalfunctionsand ordamagetotheapplianc...

Page 8: ...rvices 6 DISPOSAL OF MATERIALS 6 1 WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed in compl...

Page 9: ...e of Copper Brass Stainless steel Other materials 6 2 INFORMATION FOR MANAGEMENT OF ELECTRIC AND ELECTRONIC APPLIANCE WASTE CON TAINING BATTERIES OR ACCUMULATORS Fig 2 Wastedisposal Thissymbol whichis...

Page 10: ...ARDBOARD SHEET CORRUGATED CARDBOARD PAP 20 SORTED waste collection PAPER Check the instructions of the com petent body APPLIANCE BAG BAG OF ACCESSORIES BUBBLEWRAP PROTECTIVE SHEET LABELS POLYETHYLENE...

Page 11: ...asoheating com it documenti 7 2 NAVEL STAND ALONE OPTIONAL Procedureifonlyvalidformodelswith NAVELSTANDALONEWi Fitechnology ATTENTION InstallationmustONLYbecarriedoutbyspecialisedpersonnel The manufac...

Page 12: ...ours the smell of paint and smoke will disappear By using the stove the varnish inside the combustion chamber could be subjected to alterations This occurrence can be attri butedtodifferentreasons ane...

Page 13: ...te Timer Sleep only with the stove on Settings Info Date and time setting To set the date and time act as follows Press the menu button Select Time and Date Select by pressing menu Scroll with the arr...

Page 14: ...with the keys Press menu to confirm and esc to exit c Screw Loading To select Screw loading only when the boiler is switched off act as follows Press the menu button Scroll to Settings using the arro...

Page 15: ...dify the with the keys Press menu to confirm and esc to exit i Smoke Fan rpm To change the parameter act as follows Press the menu button Scroll to Settings using the arrows Press menu to confirm Scro...

Page 16: ...at output the ambient temperature and the big flame see Fig 11 If the ambient temperature value exceeds the limit set on the button panel in the temperature set the heat output is brought toitslowestv...

Page 17: ...or Fire Press menu to access the selected option Modify with the keys Press menu to confirm and esc to exit Set Room T this function allows setting the desired temperature in the room where the stove...

Page 18: ...operoperationofthetimer There are sixTIMER programmes for each one the user can decide the start up and shutdown time as well as the day of the week in which it is active Whenoneormoreprogrammesareact...

Page 19: ...vate the Auto Eco mode and adjust the time refer SETTINGS MENU a pag 13 Thepossibilitytoadjustthe tOffTimeEco comesfromtheneedtoensureproperoperationinthevariousroomstheboilercan be installed in and p...

Page 20: ...arameters The Easy Set feature makes it possible to adjust combustion more easily in the event that one should notice that the stove does not properly burn the fuel In the Settings menu under the head...

Page 21: ...horisedtechnician ActivatesonlywiththeEasySetfunctiondisabled SET 0 If the installation presents difficulties for smoke evacuation no draught or no pressure in the duct the smoke and ash expulsion spe...

Page 22: ...he weight Percentage of ash max 1 2 of the weight A1 less than 0 7 Diameter 6 1 8 1 mm Length 3 40 mm Content 100 untreated wood without the addition of binding agents The company recommends using cer...

Page 23: ...endowed with a ventilation system The air blown from fans keeps the appliance at a low temperature range in order to avoid high stresses to the materials which make it up Do not cover the hot air out...

Page 24: ...bling start up or stopping the product when the temperature drops below the preset value 12 3 CONTACT THERMOSTAT IN THE FUEL HOPPER If the temperature exceeds the preset safety level it immediately sh...

Page 25: ...ed Clogged flue Damaged ignition resistance A02 The fire goes off abnormally Check the level of pellets in the hopper A03Thermostat alarms The temperature of the pellets hopper or the water temperatur...

Page 26: ...ely the whole system chimney included must be cleaned and checked more frequently In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer 13 2 BEFORE...

Page 27: ...and will release a written declaration of the safety of the appliance This operation must be executed at least once a year 13 6 GENERAL CLEANING For cleaning external and inner parts of the stove do...

Page 28: ...orTechnicalAssistanceCentre during thenecessaryannualendofseasonscheduledmaintenanceoperations Thiswaythepaintwillprotecttheinnerpartsofthecom bustion chamber blocking any type of oxidative process Fi...

Page 29: ...SOLVING Before of every Authorized Technician intervention the same Technician has the duty to check if the parame tersofthemotherboardcorrespondtothoseofthetableyouown Incaseofdoubtsregardingtheuseo...

Page 30: ...loading Check if on the display there is an ACTIVE ALARM Have the stove checked Flames are weak and orange coloured pellets do not burn properly and the glass blackens Not sufficient com bustion air...

Page 31: ...lisation can be noxious to health The stove is at its highest power but does not heat up Ambient temperatu re reached The stove is at its minimum value Increase the desired ambient temperature Stove r...

Page 32: ...104 mg Nm3 Heat output Nominal heat output Pnom 9 1 kW Minimum heat output indicative Pmin 2 4 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 88 7 Useful efficie...

Page 33: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 00 2022...