background image

5

ATRIUM AT 5kW-ROXY-MADISON-SOLO-TABLA

 

 SAFETY REQUIREMENTS 

 

 

 

•  Installation, electrical connection, functional verification and maintenance must only be 

performed by qualified or authorised personnel.

•  Live electrical parts: disconnect the product from the 230V power supply before perfor-

ming any maintenance operation. Only power the product after completing assembly.

•  Special maintenance must only be performed by authorised and qualified personnel.

•  All local regulations, including those referring to national European standards, must be 

respected during appliance installation.

•  The manufacturer declines any responsibility in case of installation which are not in com-

pliance with current regulations, in case of a wrong room ventilation system, in case of an 

electric connection which is not in compliance with regulations and in case of a wrong use of 

the appliance.

•  It is forbidden to install the stove in bedrooms, bathrooms and in rooms used for storing 

combustible materials and in one-room flats.

•  The installation in one-room flats is allowed if they are in sealed chamber.

•  In any case the stove must not be installed in rooms where it can get in touch with water or 

water splashes because this can cause burn hazards and short-circuit.

•  Please check that the floor has an adequate load capacity. If the existing one does not 

satisfy this requirement, appropriate measure should be provided (for example a plate for di-

stributing the load).

•  For safety fire regulations the distances  from flammable or sensible to heat objects (sofas, 

pieces of furniture, wooden covering, etc...) must be respected.

•  If there are highly flammable objects (curtains, fitted carpet, etc...), all these distances 

must be further increased with 1 meter.

•  If the floor is made of combustible material, we recommend using a protector made of in-

combustible material (steel, glass, etc.) that also protects the front part from any falling burnt 

particles during cleaning.

•  The electrical cable must not get in touch with the fume exhaust pipe and nor with every 

other part of the stove.

•  The user, or whoever is operating the product, must read and fully understand the contents 

of this installation and use guide before performing any operation. Errors or incorrect settings 

can cause hazardous conditions and/or poor operation.

•  The type of fuel to use is only the pellets.

•  Do not use the appliance as waste inceneretor.

•  Do not place laundry on the product to dry. Any clothes horses or similar objects must be 

kept at a safe distance from the product. Fire hazard.

•  It is forbidden to operate the product with the door open or the glass broken.

•  It is forbidden to modify the appliance without authorization. 

•  Do not use flammable liquids during the ignition (alcool, petrol, oil, etc...).

•  After a failed ignition the burning pot must be empty from the amassed pellets, before 

starting the stove up again.

•  The pellet hopper must always be closed with its own lid. 

•  Before of every intervention leave the fire completely extinguish till the cooling and always 

disconnect the plug from the electric socket.

•  This appliance can be used by children aged from 8 years and above and persons with re-

duced physical, sensory or mental capabilities or lack of experience and knowledge if they 

have been given supervision or instruction concerning use of the appliance in a safe way and 

understand the hazards involved. Children shall not play with the appliance. Cleaning and 

user maintenance shall not be made by children without supervision.

•  Packaging are not toys and could cause suffocation or strangulation and other health ha-

zards! People (childreen included) with reduced mobility, psycological deseases or without 

Summary of Contents for ROXY

Page 1: ...EN USER MANUAL Pellet Stove ROXY ATRIUM 5 AIRTIGHT TABLA SOLO 5 MADISON 5 OriginalInstructions 2022CADELsrl Allrightsreserved Tuttiidirittiriservati new...

Page 2: ...ITCHING OFF 20 8 10 CONNECTIONTOTHE EXTERNALTHERMOSTAT 20 9 FUEL 21 9 1 FUEL 21 9 2 PELLET SUPPLY 21 9 3 PELLET REFUELLINGTIMER 22 10 VENTILATION 22 11 REMOTE CONTROL OPTIONAL 22 12 SAFETY DEVICES AND...

Page 3: ...gthosereferringtonationalandEuropeanstandards mustbeobservedwheninstallingtheappliance In Italy for the installation of systems with a biomass below 35KW refer to the Ministerial Decree 37 08 and the...

Page 4: ...perating conditions increase the risk of premature wear of the product especially those parts exposed to the direct heat of the fire e g combustion chamber theoriginalconditionofwhichcanundergomodific...

Page 5: ...1 meter If the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during clea...

Page 6: ...uetothepaintheatingupforthefirsttime Therefore make sure the room it is installed in is well ventilated Periodically check and empty the inspectionable parts of the smoke duct e g Tee fitting caps Hav...

Page 7: ...document to theTechnical Assistance Office Theguaranteedoesnotcovermalfunctionsand ordamagetotheappliancethatariseduetothefollowingcauses Damage caused during transportation or relocation All parts th...

Page 8: ...ARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed in compliance with laws related to safety an...

Page 9: ...LATORS Fig 2 Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators inclu...

Page 10: ...LASTIC Check the instructions of the com petent body STRAP TAPE POLYPROPYLENE PP 5 SORTED waste collection PLASTIC Check the instructions of the com petent body SCREWS STAPLES FOR STRAP FASTENING BRAC...

Page 11: ...imney flue is efficient Switch on the stove at Power 5 for at least 2 hours in order to enable the materials which make up the boiler and the fireplace to adjust the inner springing stress After 2 hou...

Page 12: ...ove s operating status Meaning of the buttons see Fig 5 Fig 5 Display 3buttons REFERENCE BUTTON DESCRIPTION MODE ACTION 1 Decreases tempera ture and power TEMPERATURE SETTING Decreases the value of th...

Page 13: ...iefly describes the menu structure this paragraph solely focuses on the selections available to the user Press the P1 button for 2 seconds to access the general programming menus Pressing P1 decreases...

Page 14: ...50 03 stop Prg 1 03 StoPPrG1 oFF 0 23 50 04 Monday Prg1 04 MondPrG1 on oFF 05 Tuesday Prg 1 05 tuESPrG1 on oFF 06 Wednesday Prg 1 06 uEdnPrG1 on oFF 07 Thursday Prg1 07 tHurPrG1 on oFF 08 Friday Prg...

Page 15: ...F 33 Wednesday Prg 4 33 uEdnPrG4 on oFF 34 Thursday Prg4 34 tHurPrG4 on oFF 35 Friday Prg 4 35 FridPrG4 on oFF 36 Saturday Prg 4 36 SAtuPrG4 on oFF 37 Sunday Prg 4 37 SundPrG4 on oFF M2 4 Weekend prog...

Page 16: ...A Flue type MAtyPEcHiMnEy 01 Flue extractor 01 Pr55SMoKEcHiMnEy da 9 a 9 MB Exit MbEScAPE 01 Exit 01 EScAPE set 8 3 1 Menu M1 CLOCK SETTING Set the current time and date The board has a lithium batter...

Page 17: ...StoP 2 dAyLy deactivation time OFF 0 23 50 Submenu M2 3 weekly program TheM2 3WeeklyProgram ProGrAMuEEK menuallowsyoutoenable disableandsettheweeklychronothermostatfunctions The weekly function has 4...

Page 18: ...37 Sund PrG4 on off Submenu M2 4 weekend program Allows you to enable disable and set the weekend chronothermostat functions day 6 and 7 i e Saturday and Sunday Enable by pressing the P3 button in 01...

Page 19: ...M6 themessagePressMore PrESSMorE willscrollonthedisplay seeFig 13 ThenpressP2 increases Thefluegasfanturnsonatmaximumspeed thefeedscrewturnson feedscrewLEDon andthey remain until the time indicated on...

Page 20: ...icalpersonnelwhocheckthateverything is installed according to the regulations in force and verifies its functionality If inside the combustion chamber there are booklets manuals etc remove them Check...

Page 21: ...lack out bLAc out lower than 5 seconds the stove turns back to the power which was settled AfteraBlack out bLAc out ofmorethan5seconds thestoveenterstheCOOLINGWAIT uAitcooLinG phase Completedthis phas...

Page 22: ...nAuthorized AssistanceService The main quality certifications for pellets currently available on the European market guarantee that the fuel complies with class A1 A2accordingtoISO17225 2 Thesecertifi...

Page 23: ...soff The loading system stops when the tank door is opened Before closing the lid make sure there are no pellets below the gasket Pellets deteriorate the gasket and eliminateitsairtightsealing vediFig...

Page 24: ...clogged exhaust Significant negative wind clogged fume passages open pellet loading tank open fire door or worn broken gaskets see SMOKE RPMVARIATION User Manual 12 2 SMOKE TEMPERATURE PROBE Detects...

Page 25: ...performs a cooling phase to the maximum 2 Performs a new ignition The display will show the message Al 1 alar al 1 Blac out AL1bLAc out see Fig 27 and the stove will shut down Fig 27 Display AL1 12 1...

Page 26: ...L6 12 15 THERMAL SAFETY OVERHEATING ALARM Occurs when the general safety thermostat detects a temperature above the trigger threshold The thermostat triggers and turns off the feed screw indicating th...

Page 27: ...cted fume tempe rature probe Have the stove checked Faulty fume temperature probe Replace the fume probe AL 3 HOT EXHAUST Faulty fume probe Replace the fume probe Faulty mother board Replace the elect...

Page 28: ...check it Blocked thermal probe Replace the thermal probe Faulty mother board Replace the mother board AL 6 NO PELLET Empty hopper Full the hopper AL 7 THERMAL SAFETY Boiler overheating Let the stove c...

Page 29: ...e P3 button pressed for some time The stove performs a check to determine whether the warning cause is still present If this is the case the warning will be shown again otherwise the stove will switch...

Page 30: ...BERTHATONLYACORRECTLYPOSITIONEDANDCLEANBRAZIERCANGUARANTEESTART UPANDOPTI MALOPERATIONOFYOURPELLETPRODUCT For the brazier to be cleaned properly remove it from its housing completely and thoroughly cl...

Page 31: ...t they must be removed with the aid of a vacuum cleaner see Fig 41 13 5 FUME PIPES ANNUAL CLEANING Clean annually from soot with brushes The cleaning operation must be executed by a specialized stove...

Page 32: ...reorTechnicalAssistanceCentre during thenecessaryannualendofseasonscheduledmaintenanceoperations Thiswaythepaintwillprotecttheinnerpartsofthecom bustion chamber blocking any type of oxidative process...

Page 33: ...LEM SOLVING Before of every Authorized Technician intervention the same Technician has the duty to check if the parame tersofthemotherboardcorrespondtothoseofthetableyouown Incaseofdoubtsregardingtheu...

Page 34: ...LARM Have the stove checked The fire extinguish and the stove stops Empty hopper Full the hopper Auger blocked by a foreign object for example nails Clean the auger Bad quality pellets Try other types...

Page 35: ...just cooled Faulty fume tempe rature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not...

Page 36: ...Nm3 Heat output Nominal heat output Pnom 7 kW Minimum heat output indicative Pmin 2 7 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 89 5 Useful efficiency at min...

Page 37: ...13 O2 121 mg Nm3 Heat output Nominal heat output Pnom 5 2 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 89 5 Useful e...

Page 38: ...NOTE...

Page 39: ...NOTE...

Page 40: ...Rev 00 2023 CADEL srl 31025 S Lucia di Piave TV Via Martiri della Libert 74 Italy Tel 39 0438 1520200 www cadelsrl com www free point it www pegasoheating com...