Fig. 34 - Display: AL 8
12.17 ALARM ALERTS
Whenever an operating condition other than that designed for the regular operation of the boiler occurs, there is an alarm condition.
The control panel gives information on the reason of the alarm in progress.
ALARM
CAUSE
SOLUTION
INTERVENTION
AL 1 - BLACK
OUT
Power cut during ignition
phase.
Clean the burning pot and switch the stove on again.
AL 2 - EXHAUST
PROBE
Disconnected fume tempe-
rature probe
Have the stove checked.
Faulty fume temperature
probe
Replace the fume probe.
AL 3 - HOT
EXHAUST
Faulty fume probe
Replace the fume probe.
Faulty mother board
Replace the electronic board.
The exchanger fan does not
work
Replace the ambient fan.
Too high pellet drop value
Adjust the pellet loading.
AL 4 - FAN
FAILURE
Faulty protection fuse of the
fume fan
Replace the fuse (1,25A).
Faulty fume fan
The pellets can burn also thanks to the chimney flue depression
and without the aid of the fume fan. Have the fume fan repla-
ced immediately. It can be noxious to health to let the stove
running without fume fan.