RIVER IDROTECH 18 - 24 - 24H2O
27
LEGEND
1
Stove
2
Cold H2O manifold
3
Hot H2O manifold
4
3-way valve
5
Electronic board
6
Zone valve
7
Radiator
8
Storage tank
9
Thermostat
10
Release pump
11
Room thermostat
12
Expansion vessel
A
Room thermostat independent from the stove (to be connected to the zone valves, if necessary)
B
Thermostat to be connected directly to the electronic board (see electrical system)
Disconnect any three-way valve and stove internal flow switch, if equipped with a DHW kit.
7.13 CONFIGURATION 5
7.13.1 System with: pellet stove connected directly to a storage tank for maintaining the temperature set and
controlled through a thermostat connected to it
All activities relating to electrical connections in the electronic board must be carried out by
authorised personnel.
Adjustable setting
SETTING
VALUES
ROOM TEMP.
Cannot be activated
EXTERNAL THERMOSTAT
ON (connect storage tank probe)
SEASON
WINTER (summer cannot be activated)
AUTO ECO
ON (it may not be disabled)
BOILER WATER TEMP.
SETTING
80 °C (to be adjusted according to the temperature chosen for
the storage tank)
Parameters to set
SETTING
VALUES
CONFIGURATION
5
Hydraulic diagram