RIVER IDROTECH 18 - 24 - 24H2O
26
LEGEND
A
Wiring diagram for connecting external thermostat and zone valve (in the case of several val-
ves, connect in parallel)
B
Wiring diagram for connecting the external thermostat
C
NTC probe to be connected directly to the electronic board (see electrical system)
D
3-way valve to be connected directly to the electronic board (see electrical system)
Disconnect any three-way valve and stove internal flow switch, if equipped with a DHW kit.
7.12 CONFIGURATION 4
7.12.1 System with: pellet stove connected directly to a storage tank for maintaining the temperature set and
controlled through a thermostat connected to it
All activities relating to electrical connections in the electronic board must be carried out by
authorised personnel.
Adjustable setting
SETTING
VALUES
ROOM TEMP.
Cannot be activated
EXTERNAL THERMOSTAT
ON (connect storage tank thermostat)
SEASON
WINTER (summer cannot be activated)
AUTO ECO
ON (it may not be disabled)
BOILER WATER TEMP.
SETTING
80 °C (to be adjusted according to the temperature
chosen for the storage tank)
Parameters to set
SETTING
VALUES
CONFIGURATION
4
Hydraulic diagram
Fig. 43 - Configuration 4