background image

5

KOBE - FENICE - SPARK - INDACO - PRINCE

 

 SAFETY REQUIREMENTS 

 

 

 

•  Installation, electrical connection, functional verification and maintenance must only be 

performed by qualified or authorised personnel.

•  Live electrical parts: disconnect the product from the 230V power supply before perfor-

ming any maintenance operation. Only power the product after completing assembly.

•  Special maintenance must only be performed by authorised and qualified personnel.

•  All local regulations, including those referring to national European standards, must be 

respected during appliance installation.

•  The manufacturer declines any responsibility in case of installation which are not in com-

pliance with current regulations, in case of a wrong room ventilation system, in case of an 

electric connection which is not in compliance with regulations and in case of a wrong use of 

the appliance.

•  It is forbidden to install the stove in bedrooms, bathrooms and in rooms used for storing 

combustible materials and in one-room flats.

•  The installation in one-room flats is allowed if they are in sealed chamber.

•  In any case the stove must not be installed in rooms where it can get in touch with water or 

water splashes because this can cause burn hazards and short-circuit.

•  Please check that the floor has an adequate load capacity. If the existing one does not 

satisfy this requirement, appropriate measure should be provided (for example a plate for di-

stributing the load).

•  For safety fire regulations the distances  from flammable or sensible to heat objects (sofas, 

pieces of furniture, wooden covering, etc...) must be respected.

•  If there are highly flammable objects (curtains, fitted carpet, etc...), all these distances 

must be further increased with 1 meter.

•  If the floor is made of combustible material, we recommend using a protector made of in-

combustible material (steel, glass, etc.) that also protects the front part from any falling burnt 

particles during cleaning.

•  The electrical cable must not get in touch with the fume exhaust pipe and nor with every 

other part of the stove.

•  The user, or whoever is operating the product, must read and fully understand the contents 

of this installation and use guide before performing any operation. Errors or incorrect settings 

can cause hazardous conditions and/or poor operation.

•  The type of fuel to use is only the pellets.

•  Do not use the appliance as waste inceneretor.

•  Do not place laundry on the product to dry. Any clothes horses or similar objects must be 

kept at a safe distance from the product. Fire hazard.

•  It is forbidden to operate the product with the door open or the glass broken.

•  It is forbidden to modify the appliance without authorization. 

•  Do not use flammable liquids during the ignition (alcool, petrol, oil, etc...).

•  After a failed ignition the burning pot must be empty from the amassed pellets, before 

starting the stove up again.

•  The pellet hopper must always be closed with its own lid. 

•  Before of every intervention leave the fire completely extinguish till the cooling and always 

disconnect the plug from the electric socket.

•  This appliance can be used by children aged from 8 years and above and persons with re-

duced physical, sensory or mental capabilities or lack of experience and knowledge if they 

have been given supervision or instruction concerning use of the appliance in a safe way and 

understand the hazards involved. Children shall not play with the appliance. Cleaning and 

user maintenance shall not be made by children without supervision.

•  Packaging are not toys and could cause suffocation or strangulation and other health ha-

zards! People (childreen included) with reduced mobility, psycological deseases or without 

Summary of Contents for PRINCE 11

Page 1: ...EN USER MANUAL Pellet Stove PRINCE 11 KOBE 11 FENICE 11 PRINCE PLUS 11 KOBE PLUS 11 FENICE PLUS 11 SPARK 11 INDACO 11 OriginalInstructions 2022CADELsrl Allrightsreserved Tuttiidirittiriservati new...

Page 2: ...16 EASYSETFEATURE SEESECTIONXSETTINGSMENU A PAG 14 20 8 17 PELLETS RECIPE SEE SECTION H SETTINGS MENU A PAG 14 21 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 14 22 8 19 CHIMNEY SWEEP FU...

Page 3: ...lost you can request another copy from the localTechnical Dept or download it directly from the company s website Alllocalregulations includingthosereferringtonationalandEuropeanstandards mustbeobserv...

Page 4: ...the interval between routine maintenance operations according to the operating condition of the product We furthermore point out that these operating conditions increase the risk of premature wear of...

Page 5: ...meter If the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleani...

Page 6: ...ntheproductisswitchedonforthefirsttime itisnormalforittoemitsmokeduetothepaintheatingupforthefirsttime Therefore make sure the room it is installed in is well ventilated Periodically check and empty t...

Page 7: ...ault the customer must have the guarantee certificate and present it with the proof of purchase document to theTechnical Assistance Office Theguaranteedoesnotcovermalfunctionsand ordamagetotheapplianc...

Page 8: ...rvices 6 DISPOSAL OF MATERIALS 6 1 WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed in compl...

Page 9: ...TORS Fig 2 Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators include...

Page 10: ...he com petent body APPLIANCE BAG BAG OF ACCESSORIES BUBBLEWRAP PROTECTIVE SHEET LABELS POLYETHYLENE LD PE 04 SORTED waste collection PLASTIC Check the instructions of the com petent body POLYSTYRENE F...

Page 11: ...US ProcedureifonlyvalidformodelswithEASYCONNECTPLUSWi Fitechnology Fig 3 EASYCONNECTPLUSmodule Fig 4 EASYCONNECTPLUSdisplay Fig 5 EASYCONNECTPLUSapp The documentation for connecting theWi Fi and using...

Page 12: ...roperty or in the event of failedoperation The Wi Fi module uses the domestic Wi Fi network ensure there is enough coverage in the place of installation N B forstoveswitha3 buttondisplay theprogrammab...

Page 13: ...tee Oily plant waste and lacquers can cause smells and smoke during the first working hours it is advisable to ventilatetheroombecausetheycouldbenoxioustopeopleandanimals Set values from 1 to 5 are de...

Page 14: ...Loading displayed only when the boiler is switched off d Tone e Ext Thermostat activation f Auto Eco activation g OffTime Eco default 5 minutes x Easy Set h Pellet Recipe i Smoke Fan rpm j ComponentsT...

Page 15: ...Scroll to Settings using the arrows Press menu to confirm Scroll to Auto Eco activation using the arrows Press menu to confirm Select On with the keys Press menu to confirm and esc to exit g OffTime...

Page 16: ...ng the arrows Press menu to confirm Scroll to the Chimney Sweep Function function using the arrows Press menu to confirm Select On with the keys Off by default Press menu to confirm and esc to exit l...

Page 17: ...blackens and the burningpottobecomeencrusted cleanthestove cleanthefumeconduitandthechimneyflue ATTENTION Makesurepelletsandashhavenotaccumulatedinthebrazierduetofailedignition Ifthebrazierisnotclea...

Page 18: ...6 Fig 14 Display Fig 15 Display Fig 16 Display Withfunction 1 or 2 or 3 or 4 or 5 thefanisforcedtoworkattheselectedoutput Forexample bysetting 3 evenifthe fan is set to heat output 5 it will work as i...

Page 19: ...or keyhighlightwiththewhitebackgroundthedayinwhichonewishestoactivatethetimerandconfirmwiththe menu key Ifno day of the week is confirmed as active in turn the timer programme will not appear active...

Page 20: ...procedure begins the panel shows Off Active Eco small flashing flame see Fig 21 When the stove is switched off the panel shows active OFF ECO with the flame icon off For an ECO switch on the following...

Page 21: ...madewiththesupportoftheauthorisedtechnician ActivatesonlywiththeEasySetfunctiondisabled SET 0 Thisfunctionisforadaptingthestovetothepelletsthatarebeingused Infact asthereareseveraltypesofpelletsonthem...

Page 22: ...causeabadcombustion afrequentburningpotobstructionandexhaustconduitsobstruction Furtherit decreases the calorific value soils the glass and increases consumptions and ash and unburnt granules quantity...

Page 23: ...pression alarm and proceeds to switch off Wait until it switches off then light it again Fig 26 Dooropen Fig 27 deterioratedgasket Fig 28 Timer 90seconds Tooperatecorrectly thestovemustworkwiththepell...

Page 24: ...mperature 0 C 50 C 38 khz infrared signal Used batteries contain metals which are harmful for the environment they must therefore be disposed of separately in the special containers Fig 30 Remotecontr...

Page 25: ...run until the flame goes out due to lack of fuel and until a minimum level of cooling is reached 12 7 TEMPORARY POWER CUT If the power cut lasts less than 10 the boiler returns to its previous operati...

Page 26: ...utine maintenance alert it does not block the system When this flashing message appears upon start up it means that the preset operating hours have elapsed before maintenance Contact the service centr...

Page 27: ...UPANDOPTI MALOPERATIONOFYOURPELLETPRODUCT For the brazier to be cleaned properly remove it from its housing completely and thoroughly clean all the holes and the grate on the bottom If good quality p...

Page 28: ...they must be removed with the aid of a vacuum cleaner see Fig 37 13 5 FUME PIPES ANNUAL CLEANING Clean annually from soot with brushes The cleaning operation must be executed by a specialized stove re...

Page 29: ...orTechnicalAssistanceCentre during thenecessaryannualendofseasonscheduledmaintenanceoperations Thiswaythepaintwillprotecttheinnerpartsofthecom bustion chamber blocking any type of oxidative process Fi...

Page 30: ...M SOLVING Before of every Authorized Technician intervention the same Technician has the duty to check if the parame tersofthemotherboardcorrespondtothoseofthetableyouown Incaseofdoubtsregardingtheuse...

Page 31: ...t loading Check if on the display there is an ACTIVE ALARM Have the stove checked Flames are weak and orange coloured pellets do not burn properly and the glass blackens Not sufficient com bustion air...

Page 32: ...elisation can be noxious to health The stove is at its highest power but does not heat up Ambient temperatu re reached The stove is at its minimum value Increase the desired ambient temperature Stove...

Page 33: ...Nm3 Heat output Nominal heat output Pnom 10 5 kW Minimum heat output indicative Pmin 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at min...

Page 34: ...0 mg Nm3 NOx al 13 O2 130 mg Nm3 Heat output Nominal heat output Pnom 10 5 kW Minimum heat output indicative Pmin 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom...

Page 35: ...35 KOBE FENICE SPARK INDACO PRINCE...

Page 36: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 00 2022...

Reviews: