![Cadel HIDROFIRE 22.8 Installation, Use & Maintenance Manual Download Page 52](http://html.mh-extra.com/html/cadel/hidrofire-22-8/hidrofire-22-8_installation-use-and-maintenance-manual_481080052.webp)
IDRO PRINCE
3
12-16-23-23 H
2
O - IDRO PRINCE 30-30 H
2
O - AQUOS
3
16-23-23 H
2
O - IDRON 16-22 AIRTIGHT - MIRA 16-22 - TESIS 16-23 AIRTIGHT - HIDROFIRE 22.8
52
11.11 SYSTEM WITH: DIRECT VENT PELLET STOVE, ROOM THERMOSTAT, AND DHW BOILER
Settable settings
:
SETTING
VALUES
WATER TEMP.
30° C - 80°C
BOILER TEMP.
30° C - 80°C
Parameters to set
:
SETTING
VALUES
Configuration
3
External thermostat
ON
Hydraulic diagram
:
8
7
4
5
2
6
8
5
6
3
1
Fig. 54 - System with: direct vent pellet stove, room thermostat, and dhw boiler
LEGEND
1
Pellet Boiler
2
Rear terminal board
3
Anti-condensate valve
4
DHW boiler
5
Boiler probe
6
3-way diverter valve
7
DHW Thermostatic Valve
8
Room thermostat
11.12 SYSTEM WITH: PELLET STOVE AND PUFFER
Settable settings
:
SETTING
VALUES
PUFFER TEMP.
55° C - 75°C