14
EASY - SWEET
3
EN
We recommend to check with your chimney flue manufacturer the safety distances which
must be respected and the type of insulating material. The aforesaid regulations are valid
also for holes made on the wall (EN 13501 - EN 13063 - EN 1856 - EN 1806 - EN 15827).
10
FUEL
10.1
FUEL
•
Use top-quality pellets because they have influence in the calorific value and in ash remains.
•
Pellets features are: dimension Ø6-7mm (D06 Class), maximum lenght 40 mm, calorific value 5kWh/kg, humidity
≤ 10%, ash remains ≤ 0,7%, they must be correctly pressed and not much mealy, without sizing agents, resins
and other additives (it is advisable to use pellets in compliance with the regulation EN14961-2 type ENplus-A1
).
•
Not adequate pellets cause a bad combustion, a frequent burning pot obstruction and exhaust conduits
obstruction. Further it decreases the calorific value, soils the glass and increases consumptions and ash and
unburnt granules quantity.
Humid pellets cause a bad combustion and running, so please assure you that they are
stored in dry places and far at least one meter from the stove and/or any other source of
heat.
•
It is advisable to try different type of pellets available on the market and to choose that which gives the best
performance.
•
The use of bad quality pellets can damage the stove so that the warranty and manufacturer liability fall.
•
On all our product are used high-quality materials such as stainless-steel, steel, cast iron, etc... These materials,
before being sold on the market, are tested in laboratory, but despite this on the components which enable
the pellets flow (auger) there could exist minimum differences in the material used, in roughness and porosity,
which could generate usual variations in fuel transportation (pellets), causing a flame raising or drapping with
a possible switching off at lower powers.
•
Depending on the type of pellets it could be necessary a parameters adjustment, please contact an
Authorized Assistance Service.
11
INSTALLATION
11.1
INTRODUCTION
•
The assembly position must be chosen depending on environment, outlet, chimney flue.
•
Check with local authorities if there are any restrictive regulations which regard the combustible air inlet,
room ventilation, fume exhaust system together with chimney flue and chimney pot.
•
Check if there is the combustible air inlet.
•
Check the probable presence of other stoves or appliances which could depress the room.
•
Check at switched on stove if there is the presence of CO in the room.
•
Check if the chimney has the necessary draught.
•
Check if during the fume passage all has been executed in safety (probable fume losses and distances from
flammable materials, etc.…).
•
The installation of the appliance must enable an easy access for appliance, fume exhaust pipes and chimney
flue cleaning.
•
The installation must enable en easy access to the electric connection plug (see
ELECTRIC CONNECTION
page 17
).
•
To install more appliances, the external air inlet must be correctly dimensioned (see
page 36
).
Summary of Contents for EASY-SWEET 3
Page 38: ...NOTE ...
Page 39: ...NOTE ...