29
EASY - SWEET
3
EN
PANEL ALERT
TYPE OF PROBLEM
SOLUTION
A02
The fire goes off abnormally.
Check the level of pellets in the hopper.
A03 Thermostat
alarms
The temperature of the pellets hopper or the
water temperature exceed the envisioned
safety threshold.
Wait for the cooling stage to end, cancel the alarm
and restart the boiler setting the fuel loading at
minimum (SETTINGS menu - Pellet Recipe).
Check that dust does not clog the aeration grid on
the stove back.
If the alarm persists, contact the service centre.
Check if the room fan works properly (if present).
A04
Smoke overheating.
The set smoke threshold has been exceeded.
Reduce pellets loading (SETTINGS menu - Pellet
Recipe).
A05 Pressure
switches alarm
Flue gas pressure switch trip.
Check for chimney obstructions/fire door opening,
pellet tank opening, gasket seals, side fire ducts
cleaning.
A08
Abnormal smoke fan operation.
If the alarm persists, contact the service centre.
A09
Smoke probe faulty.
If the alarm persists, contact the service centre.
SERVICE
Routine maintenance alert (it does not block
the system).
When this flashing message appears upon start-up, it
means that the preset operating hours have elapsed
before maintenance. Contact the service centre.
13.12
ALARM RESET
To reset the alarm you must keep the 1 (ESC) button pressed for some time. The stove performs a check to
determine whether the warning cause is still present.
If this is the case, the warning will be shown again, otherwise the stove will switch to the OFF position.
If the warning is still present, contact a service centre.
14
MAINTEINANCE
14.1
INTRODUCTION
For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
•
Fume outlet pipes (fume c chimney flue + chimney pot) must always be cleaned, scrubbed and
checked by an authorized technician in compliance with local regulations, with the instructions of the
manufacturer and those of your insurance company.
•
If there are no local regulations and no instruction from your insurance company, it is necessary to have your
fume pipe, chimney flue and chimney pot cleaned at least once a year.
•
It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and
the electronical elements checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance
Service.
•
After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
•
If the stove had been using continuously and intensely, the whole system (chimney included), must be
cleaned and checked more frequently.
•
In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer.
14.2
BURNING POT AND ASH TRAY CLEANING
The burning pot and ash tray cleaning must be executed at least every 2 days.
•
Open the door.
Summary of Contents for EASY-SWEET 3
Page 38: ...NOTE ...
Page 39: ...NOTE ...