At this point it will propose 00:00 as starting time, with key + - adjust the starting time and press the “menu” key
to confirm.
The next step proposes a shutdown time of 10 minutes above that set for start-up: press the + key and adjust the
shutdown time, confirm with the “menu” key.
Subsequently the system proposes the days of the week in which to activate or deactivate the previously set
timer. With the - or + key highlight with the white background the day in which one wishes to activate the timer
and confirm with the “menu” key. If no day of the week is confirmed as active, in turn the timer programme will
not appear active in the status screen.
Continue to program the following days or press “ESC” to exit. Repeat the procedure to program the other
timers.
12.12
PROGRAMMING EXAMPLES:
P1
P2
on
off
day
on
off
day
08:00
12:00
mon
11:00
14:00
mon
Boiler on from 08:00 to 14:00
on
off
day
on
off
day
08:00
11:00
mon
11:00
14:00
mon
Boiler on from 08:00 to 14:00
on
off
day
on
off
day
17:00
24:00
mon
00:00
06:00
tue
Boiler on from 17:00 on monday to 06:00 on tuesday
12.13
NOTES FOR TIMER OPERATION
•
Start-up with the timer always takes place with the last temperature and ventilation settings (or with default
20°C and V3 settings in the event they have never been changed).
•
Start-up time ranges from 00:00 a 23:50
•
If the shutdown time is not already memorised, it proposes a start-up time in + 10 minutes.
•
A timer programme switches the boiler off at 24:00 of one day and another programme switches it on at 00:00
of the next day: the boiler stays on.
•
A programme proposes a start-up and shutdown in times included within another timer programme: if the
boiler is already on, start will not have any effect, while OFF will switch it off.
•
In the boiler on and timer active condition, press the OFF key and the boiler will switch off, it will switch on
automatically at the next time set on the timer.
•
In the boiler off and timer active condition, press the ON key and the boiler will switch on, it will switch off at
the time set on the active timer.
12.14
AUTO ECO MODE (SEE SECTION F-G SETTINGS MENU PAGE 20)
To activate the “Auto-Eco” mode and adjust the time refer
SETTINGS MENU page 20
.
The possibility to adjust the “Off Time Eco” comes from the need to ensure proper operation in the various rooms
the boiler can be installed in and prevent continuous shutdowns and start-ups in the event the temperature is
subject to sudden changes (air currents, poorly insulated rooms, etc.).
The ECO switch off procedure is automatically activated when the power recall device is activated (Room
probe +1°C or external thermostat with open contact, see
Fig. 36 page 24
). "Off Time Eco" time decrease starts
(5 minutes by default, see
Fig. 37 page 24
, and can be modified from the "Settings" menu). During this phase
the panel view is activated with the small flame and alternates chrono (if on) - active Eco.
Fig. 36 - Active eco 1
Fig. 37 - Active eco 2
Fig. 38 - Active eco 3
On the upper display the minutes for the Eco Stop countdown are shown. The flame goes to P1, where it remains
until the set "Off Time Eco" time is over and, if conditions are still met, it switches to the switch-off process. The ECO
switch-off countdown is reset if one of the devices resumes recalling power.
When the switch-off procedure begins, the panel shows: Off - Active Eco - small flashing flame (see
Fig. 38 page
24
).
When the stove is switched off, the panel shows active OFF-ECO with the flame icon off.
For an ECO switch on, the following conditions must be met simultaneously:
•
Room probe -1°C or external thermostat with closed contact (for at least 20" to avoid false recalls).
Summary of Contents for EASY-SWEET 3
Page 38: ...NOTE ...
Page 39: ...NOTE ...