CADDX NX148-E Installation Manual Download Page 15

15

The following chart provides the device numbers that will be reported for trouble conditions.

KEYPAD

PARTITION

1

2

3

4

5

6

7

8

1

192

193

194

195

196

197

198

199

2

200

201

202

203

204

205

206

207

3

208

209

210

211

212

213

214

215

4

216

217

218

219

220

221

222

223

5

224

225

226

227

228

229

230

231

6

232

233

234

235

236

237

238

239

7

240

241

242

243

244

245

246

247

8

248

249

250

251

252

253

254

255

NX148-E MAXIMUM WIRE RUN

(Note:  These numbers are for one keypad at the end of the wire. When connecting more than one keypad to the

end of the wire, a heavier gauge wire will be required.)

WHEN CONNECTED TO NX8-E

WHEN CONNECTED TO NX-320

Length in feet

Wire Gauge

Wire Gauge

250'

24

22

500

20

18

1000

18

16

1500

16

14

2500

14

12

SYSTEM NOTES

Summary of Contents for NX148-E

Page 1: ...AD 5 SET KEYPAD OPTIONS 6 SET KEYPAD NUMBER AND PARTITION 7 KEYPAD FUNCTIONS 7 READING THE EVENT LOG 7 SET ELAPSED INCREMENTS SINCE LAST AUTOTEST 8 SET SYSTEM TIME AND DATE 8 ADJUST KEYPAD TONE 8 VIEW...

Page 2: ...on the bottom line with the numbers 1 8 in the first 8 characters If the number appears this binary switch is on If a minus sign appears where the number should be this switch is off Toggle numbers on...

Page 3: ...ER RUMPUS STAIRS WINDOW BATHROOM DURESS HEAT MICROWAVE SAFE STORAGE WING BEAM EAST HOLDUP MOTION SENSOR STUDY WIRELESS BEDROOM EMERGENCY HOUSE NORTH SHOCK TAMPER YARD BUTTON EXIT INFRARED NURSERY SHOP...

Page 4: ...the control panel NOTE All modules should be connected and set to unique addresses prior to enrolling modules To enroll the modules enter the Program Mode of the NetworX control panel When the Progra...

Page 5: ...e keypad numbers with U 9 4 prior to programming custom messages If a keypad is added after messages are programmed you should either program ALL messages in it or enter custom message programming on...

Page 6: ...hart The current state of the option will be shown in the lower right corner of the display Press U to advance to the next option without making changes Otherwise follow the directions on the bottom l...

Page 7: ...September 25 th at 5 27 p m by user 75 The U shows that this event is not programmed to be reported to the central monitoring station POSSIBLE LOG MESSAGES DISPLAY DESCRIPTION TXlobat Transmitter Low...

Page 8: ...Code Entry A code has been entered First Open First Open Reports when the first partition is disarmed Last Close Last Close Reports when the last partition is armed Sprnklr Sprinkler Instant sprinkler...

Page 9: ...LCD Screen will prompt to Select Light Number 0 9 2 Enter the number of the device to edit The LCD will display the light number on the left On the right side of the display it will prompt to turn the...

Page 10: ...digit NX8E user number Remember to use leading zeros i e 03 or 003 for user 3 The LCD will now prompt you for the first in the following list of attributes PROMPTS 1 Outputs used Open Close Rprt Bypas...

Page 11: ...sly To set the multi partition mode use the U 9 3 function and answer YES to the question Master keypad NOTE U 1 followed by a code will temporarily access the Master Mode The keypad will revert back...

Page 12: ...e Arm Dash Flashing Area Armed Instant Area Dash Area Disarmed Ready to Arm Dash Area Area is Armed To disarm all of the areas press the x up scroll key To arm all of the areas press the down scroll y...

Page 13: ...ore of the following fault messages will be displayed Use the scroll keys to browse through them To exit the service messages press RQWURO 2YHU XUUHQW A short circuit of a control s power supply has o...

Page 14: ...QVLRQ 5 DPPHG A radio receiver is being jammed SDQVLRQ 7URXEOH An expansion device or keypad is not reporting to the control panel SDQVLRQ 6LUHQ WURXEOH An expansion device has detected some form of t...

Page 15: ...24 225 226 227 228 229 230 231 6 232 233 234 235 236 237 238 239 7 240 241 242 243 244 245 246 247 8 248 249 250 251 252 253 254 255 NX148 E MAXIMUM WIRE RUN Note These numbers are for one keypad at t...

Page 16: ...0 degrees F CURRENT DRAW 110 mA Maximum 75 mA without Sounder LCD KEYPAD DIMENSIONS 6 4 Wide 5 3 High 1 0 Deep SHIPPING WEIGHT 2 lbs CADDX CONTROLS INC 1420 NORTH MAIN STREET GLADEWATER TEXAS 75647 TO...

Reviews: