RESETTING YOUR SECURITY CONTROL CENTER

In the event of a system malfunction in the Security Control Center, press the [#] (reset) key
on the keypad control. This should reset the code sequence and restore normal operation. If
the problem persists, call the service number located on page 1 of this booklet for service. 

AUDIBLE ALARM SOUNDS

FIRE: Steady siren,  pulsing bell (see page 1) or beeping keypad.

INTRUSION & PANIC: Yelp siren, steady bell (see page 1) and beeping keypad.

KEYPAD CONTROL LIGHT INDICATORS

ARMED

RED: On when system is armed; off otherwise. Flashes for alarm memory if alarm
was activated during arming cycle.

READY

GREEN: On when all zones are secure  and/or Bypassed and the system is ready
to arm; off otherwise. Flashes for telephone line fault.

INSTANT RED: On when the entry/exit zones are instant; off otherwise.

POWER

RED: On when AC power is on; off otherwise. Flashing when the system standby
battery is low.

ZONES

YELLOW: Flashing means unsecured. Steady means bypassed. Off means
secure.

 

KEYPAD CONTROL TONES (BEEPS)

A sounder is built into the keypad and may sound for any of the following reasons:

Beeps for all keypresses.

  Sounds a continuous tone during the Entry delay time.

  Pulses when a day zone is violated while the system is disarmed.

  Pulses when a FIRE zone has a trouble condition; there is a low battery, or bell circuit

trouble.

  Pulses when the armed status changes and the AC power is off.                      

  Beeps 3 times for trying to arm with the "READY" light off, if "FORCE ARMING" has not

been selected.

Beeps 1 second for the "CHIME" feature.

  Beeps 1 second at the end of the exit delay.

  Beeps to indicate telephone line fault if selected.

   Beeps 1 long beep followed by 3 short beeps to alert you that there are only ten seconds

remaining in the exit delay.

When pulsing, the keypad sounder may be silenced by entering a valid code. The arm/disarm
state of your system will not change when entering a code to silence a pulsing keypad
sounder. 

www.ealarm.com.my

Summary of Contents for 8600

Page 1: ...LATES SPECIFICALLY WITH TWO MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system YOU SHOULD BE AWARE OF THE FOLLOWING FACTS AND USE THEM WHEN PREPARING A SAFETY SECURITY PLAN FOR YOUR HOME BUSINESS 1 Your security system is an electron...

Page 2: ...ssed NOTE If the exit door is open when the exit delay expires the siren will sound and the entry delay will begin If a valid code is not entered prior to the expiration of the entry delay an alarm report will be transmitted to the monitoring station if the system is monitored Entering a valid code during the entry delay will disarm the system silence the siren and keep an alarm report from being ...

Page 3: ...installing company may have programmed the INSTANT option to occur in conjunction with the AUTOMATIC BYPASS feature In this case the INSTANT light and the bypassed ZONE lights will become illuminated at the end of the exit delay If this occurs you still have the ability to turn the INSTANT feature off and or on by pressing the U key GROUP BYPASS OPTION K If checked the GROUP BYPASS option has been...

Page 4: ...ond to the Panic Hold Up activation KEYPAD ACTIVATED FIRE ALARM If checked this feature has been selected by your installing company If so you can activate the Fire alarm by pressing the one 1 and three 3 keys at the same time for one second If your system is connected to a monitoring center an emergency report could be sent to that center These keys should only be pressed in an emergency situatio...

Page 5: ...de 1 and up to 13 auxiliary codes All codes must have 4 digits These Auxiliary codes are individually numbered from 2 to 14 NOTE If your system is programmed for a DURESS code mentioned above user code 7 will not be available If Auxiliary codes are desired they must be programmed individually Codes 2 thru 7 can be changed by the procedures described below while codes 8 thru 14 can only be changed ...

Page 6: ... the system standby battery is low ZONES YELLOW Flashing means unsecured Steady means bypassed Off means secure KEYPAD CONTROL TONES BEEPS A sounder is built into the keypad and may sound for any of the following reasons Beeps for all keypresses Sounds a continuous tone during the Entry delay time Pulses when a day zone is violated while the system is disarmed Pulses when a FIRE zone has a trouble...

Page 7: ...one light should blink Walk into all areas protected by motion detection devices while someone observes the Keypad Control The appropriate yellow zone light should blink for each sensor tested If your system has a FIRE Zone the Smoke or Heat detectors should be tested at least monthly If your Security System is monitored by a Central Monitoring Station always call before to let them know that you ...

Reviews: